Commit Graph
26 Commits
Author SHA1 Message Date
jaredandClaude Opus 5.5 d07787ee38 Monitor: keep checking interfaces whose link-down alert is still open
Lint / JS (eslint) (push) Successful in 8s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 53s
Test / Python Tests (pytest) (push) Successful in 1m3s
Lint / Python (flake8) (pull_request) Successful in 55s
Lint / JS (eslint) (pull_request) Successful in 6s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m22s
Test / Python Tests (pytest) (pull_request) Successful in 1m27s
After the interface baseline is reset, a port that is already down reads as
"first seen down", which neither alerts nor resolves. An alert opened before
the reset was then stuck open without updates: micro1's enp3s0 had sat at
one failed check since March with no ticket. An interface with an open
interface_down alert is now treated as previously up, so the alert keeps
counting, tickets and resolves as normal.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-11 01:02:53 -05:00
jared 0243b23732 Merge remote-tracking branch 'origin/main' into zimaboard-and-facing
Lint / Python (flake8) (push) Successful in 58s
Lint / JS (eslint) (push) Successful in 8s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / JS (eslint) (pull_request) Successful in 13s
Security / Python Security (bandit) (push) Successful in 1m11s
Test / Python Tests (pytest) (push) Successful in 1m14s
Security / Python Security (bandit) (pull_request) Successful in 1m44s
Test / Python Tests (pytest) (pull_request) Successful in 1m40s
Lint / Python (flake8) (pull_request) Successful in 48s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
# Conflicts:
#	static/style.css
#	tests/test_cutsheet.py
2026-11-11 00:46:13 -05:00
jaredandClaude Opus 5.5 a9de175d90 Rack: ports-facing separate from posts, three views, ZimaBoard 832 shelves to scale
Lint / JS (eslint) (push) Successful in 8s
Lint / Python (flake8) (push) Successful in 1m0s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m9s
Lint / Python (flake8) (pull_request) Successful in 57s
Test / Python Tests (pytest) (push) Successful in 1m14s
Lint / JS (eslint) (pull_request) Successful in 8s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 1m5s
Gear on the rear posts usually still faces the front (the StarTech's RPDU
and ZimaBoard shelf), so "which posts" and "which way the ports face" are
now separate fields (mount, facing). The page has three views: Front (front
posts), Rear posts (rear-post gear seen from the front, i.e. what is behind
the front gear) and Rear (from behind). An item seen from the side it
doesn't face shows its back. Facing defaults to front, so existing items
keep their meaning.

Shelves are drawn at true scale with their contents ordered by a new
"Position on shelf". The IceWhale ZimaBoard 832 is traced from IceWhale's
labelled photo of its port end (ZimaDocs): Mini-DP, two RJ45-over-USB 3.0
stacks with link/activity LEDs, DC jack, gunmetal case, gold PCB edge and
black base. Its RJ45 link lights follow the host's physical NICs and the
status glow follows the host.

New cutsheet_items columns facing and slot, added on first use.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-11 00:12:07 -05:00
jaredandClaude Opus 5.5 ce12dede5f Faceplates: USW Pro Max 24 PoE and 48 PoE
Lint / JS (eslint) (push) Successful in 12s
Lint / Python (flake8) (push) Successful in 1m10s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m11s
Test / Python Tests (pytest) (push) Successful in 1m42s
Lint / Python (flake8) (pull_request) Successful in 2m28s
Lint / JS (eslint) (pull_request) Successful in 14s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m10s
Test / Python Tests (pytest) (pull_request) Successful in 1m16s
Both laid out from the CC0 NetBox devicetype-library images, with jack
centres measured from them: the 24 has one row of 24 RJ45 in groups of 8
(17-24 at 2.5G) and 2 SFP+; the 48 has two rows, odd ports on top, in
groups of 16 (33-48 at 2.5G) and 4 SFP+ (49-52). The "2.5G" and "10G" bars
under the faster ports are drawn too (fpSpeedBar).

Registered as USPM24P/USPM48P with USPM24/USPM48 aliases, and as Front
drawing options so the new switch draws on the rack before it is adopted.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-11 00:01:12 -05:00
jaredandClaude Opus 5.5 50db56cdcb Rack: draw the UniFi UACC blank 24-port keystone patch panel
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 58s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Python (flake8) (pull_request) Successful in 1m6s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (push) Successful in 1m0s
Test / Python Tests (pytest) (push) Successful in 1m59s
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 1m0s
Front drawing "UniFi Patch Panel Blank 24" draws the real panel, laid out
from the CC0 NetBox devicetype-library image: grey steel face, darker ears
with oval holes, 24 keystone openings with the cable-support bar behind
them, and a cable slot at each end. Ports with a documented cable get a
keystone jack; cutsheet marks, port labels and run highlighting work as on
the generic panel.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 23:39:27 -05:00
jaredandClaude Opus 5.5 619a2c913d Remove em and en dashes from the UI, code and docs
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 57s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Python (flake8) (pull_request) Successful in 51s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m0s
Test / Python Tests (pytest) (push) Successful in 1m3s
Test / Python Tests (pytest) (pull_request) Successful in 52s
Page titles read "Rack | GANDALF", ranges use a hyphen (U26-42,
1-100 of 300), empty cells show "-", and dash-separated phrases use a
colon, comma or full stop. In the shared base.js only the on-screen strings
changed (boot line, placeholders, offline banner and toast).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 23:37:56 -05:00
jaredandClaude Opus 5.5 0f4e129c20 Rack: drawn fronts for the NVR and server cases
Lint / JS (eslint) (push) Successful in 15s
Security / Python Security (bandit) (push) Successful in 1m5s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (push) Successful in 1m0s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 57s
Items Gandalf has no live faceplate for can pick a Front drawing: the
UniFi NVR Pro (drawn from the CC0 NetBox devicetype-library image), the
Sliger CX4712 4U and Rosewill RSV-L4500U 4U cases (from driveAtlas's
layouts), and generic 1U/2U/4U servers. The power light shows the linked
device's live status. They export with the rest of the rack.

New cutsheet_items column chassis, added on first use.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 23:25:02 -05:00
jaredandClaude Opus 5.5 c50e1f8322 Rack: front and rear mounting, rack settings in the page
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 51s
Lint / Python (flake8) (pull_request) Successful in 55s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 52s
Test / Python Tests (pytest) (pull_request) Successful in 55s
Items are mounted from the front, the rear, or full depth. On a 4-post
rack a front and a rear item can share a unit; a full-depth one takes
both sides, and the rear view shows its back. Overlaps are checked per
side. Shelf contents take the shelf's side. A Front / Rear switch flips
the drawing.

Racks are saved in Gandalf (new cutsheet_racks table) and edited on the
rack page by admins: name, height, notes, add and delete. Renaming moves
the rack's items; saving the first rack carries over the items of the
config default it replaces. Config racks remain the fallback.

Faceplates are stretched to the full width only when the drawing is
close to the slot's proportions, so the PDU is not squashed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 22:35:37 -05:00
jaredandClaude Opus 5.5 bdd68a397d Rack: link items to devices, shelves, several racks, export; fix layout and light mode
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 48s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 49s
Lint / Python (flake8) (pull_request) Successful in 51s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 50s
Test / Python Tests (pytest) (pull_request) Successful in 53s
Cutsheet items gain a "Gandalf device" link, so an item named after the
product (UDM-Pro) shows the live device's faceplate, ports and status.
Cable checks, suggestions, tickets and the device page treat an item and
its linked device as one. Without this, product-named items drew as bare
name plates.

Items can sit on a shelf instead of a rack unit; the shelf draws what is
on it with live status. Items have a rack, the page shows a tab per rack
(config "racks"), and a rack can be downloaded as SVG or PNG.

The rack is centred, long runs of empty units fold into one band (with a
toggle), every device fills the 19" width, the UPS shows its front only,
and the rack keeps its own palette so it reads in light mode.

New cutsheet_items columns rack, shelf and device are added on first use.
Deleting a shelf, or making it something else, is refused while it holds
items; renaming it carries over.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 21:44:59 -05:00
jaredandClaude Opus 5.5 f655836446 Add a rack drawing (/rack)
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 50s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 50s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / Python (flake8) (pull_request) Successful in 52s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m2s
The rack front is drawn from the rack units on cutsheet items. Switches
with a faceplate use it, with live port state; patch panels get a generic
panel with port labels; everything else is a labelled plate. Each
documented port shows its cutsheet state, and hovering a port lights up
every port on the same cable run (through patch panels) and names the
cables. Clicking opens the switch port or the cable.

Overlapping items and items past the top of the rack are listed instead
of drawn over another; where two claim the same top unit, the first one
recorded wins. rack.units sets the height (default 42).

/api/rack builds on the cutsheet view; cutsheet.rack_layout and
cutsheet.port_marks hold the placement and per-port logic.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 20:59:30 -05:00
jaredandClaude Opus 5.5 c262e5ecc8 Inventory links, cutsheet marks on faceplates, and single page titles
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 54s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 19s
Test / Python Tests (pytest) (push) Successful in 2m6s
Security / Python Security (bandit) (pull_request) Successful in 1m18s
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 1m1s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Device pages get an Inventory button: it opens the device's HomeBox record
once an admin pastes its URL (stored in the new device_links table; only
URLs on inventory.base_url are accepted), and searches the inventory for
the model until then. Tickets link the record too.

Faceplate ports with a documented cable get a corner dot: green matches,
red mismatch, grey documented but unconfirmed. The port's tooltip names
the cable, and a legend toggle (remembered per browser) hides them.

Page titles no longer repeat GANDALF ("Alert History - GANDALF - GANDALF").

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 20:47:14 -05:00
jaredandClaude Opus 5.5 9d561db703 Add an alert history page and tie /health staleness to the poll interval
Lint / JS (eslint) (push) Successful in 6s
Lint / Python (flake8) (push) Successful in 1m56s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 2m3s
Test / Python Tests (pytest) (push) Successful in 1m0s
Lint / Python (flake8) (pull_request) Successful in 48s
Lint / JS (eslint) (pull_request) Successful in 6s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m7s
Test / Python Tests (pytest) (pull_request) Successful in 2m6s
/events lists every alert from the last 24 hours to 90 days, open or
cleared, with how long each lasted, failed checks and its ticket. Filters
(device, type, severity, state, range) live in the URL, so device pages
and tickets link straight to a device's history. A "Recurring" table
lists alerts that fired more than once on the same target. On phones the
rows become cards.

/api/events/history backs it (100 per page). The existing /api/events is
unchanged.

/health and the dashboard's monitor indicator now call the monitor
stalled after five missed polls (at least 10 minutes) instead of a fixed
20, and /health reports the monitor's age.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 20:29:09 -05:00
jaredandClaude Opus 5.5 437f7a415f Add recovery notes and fuller context to tickets
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m26s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m30s
Lint / Python (flake8) (pull_request) Successful in 52s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m28s
Test / Python Tests (pytest) (pull_request) Successful in 2m0s
When an alert that opened a ticket clears, the monitor now comments on the
ticket (when it cleared, how long it lasted, failed checks, a link back).
It never closes or changes a ticket's status. Failed notes retry each
cycle for 24 hours; a 401/403 from Tinker stops them until restart.

Tickets are now Markdown with a "What to check" list and, where known:
the switch port the device plugs into (kept from the last time it was
seen, so a dead host still shows it), cutsheet cables and their path,
how often the alert fired in the last 7/30 days, other open alerts on the
device, and links into Gandalf (gandalf.public_url). Titles are unchanged
so Tinker's duplicate detection still works.

network_events gains recovery_notified, added at monitor startup; rows
that cleared before the upgrade count as already notified.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 19:44:50 -05:00
jaredandClaude Opus 5.5 86aa29b378 Cutsheet trace mode and mismatch alerts
Lint / Python (flake8) (push) Successful in 1m8s
Security / Python Security (bandit) (push) Successful in 56s
Test / Python Tests (pytest) (push) Successful in 43s
Lint / Python (flake8) (pull_request) Successful in 50s
Lint / JS (eslint) (pull_request) Successful in 30s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 55s
Test / Python Tests (pytest) (pull_request) Successful in 50s
Lint / JS (eslint) (push) Successful in 16m17s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Trace a cord: pick a panel port, press Start, and unplug the cord at the
panel. The page polls a new admin-only endpoint that reads every switch
port's state from UniFi (cached 2 s), shows the one port that dropped
with a button to record the cable, and confirms when it's plugged back
in. Several ports dropping at once, or none within 3 minutes, is
explained rather than guessed at.

Mismatch alerts: the monitor runs the cutsheet check every poll. Each
mismatched installed run (wrong neighbor, no link, missing port, port
conflict) keeps one cable_mismatch event on its switch, resolved when
fixed, and opens a P4 ticket after cutsheet.mismatch_ticket_hours
(default 24, 0 never). Suppressing the switch or port stops the ticket.

Also fixes buttons with the hidden attribute still showing, which left a
Delete button on the new-cable form.

Closes #12

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 16:54:57 -05:00
jaredandClaude Opus 5.5 b9412ff6ba Add cutsheets: planned cabling checked against discovery
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m36s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m40s
Lint / Python (flake8) (pull_request) Successful in 52s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m13s
Test / Python Tests (pytest) (pull_request) Successful in 1m15s
A new Cutsheet page records where every cable is meant to go and compares
it with what Gandalf discovers.

- Inventory for what discovery can't see: patch panels, wall jacks,
  shelves and rack positions. Panels and jacks pass through front to rear.
- Cables with two endpoints, ID, type, length, color, status (planned,
  installed, dark, retired) and notes; the far end may be unterminated.
- Each cable's full run is traced through panels and jacks, and runs
  ending on a switch port are checked against its discovered neighbor
  (LLDP, client table, or a DAC serial seen at both ends): matches,
  wrong neighbor, no link, missing port, port conflict, unverified, idle.
- Undocumented links: live switch ports no cable mentions, one click to
  add with what Gandalf already knows. Port panels show the planned cable.
- Labels to make: cable IDs and panel-port labels not yet applied, with a
  print view, for a handheld label maker.
- CSV export, and all-or-nothing import that upserts by cable ID.
- Cables, panels and jacks appear in the dashboard search.

Editing needs the admin group and a JSON request body. Every change is
written to cutsheet_history in the same transaction. Tables are created
on first use.

Refs #12

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 16:05:08 -05:00
jaredandClaude Opus 5.5 7e588e5b02 Keep every switch port and show SFP modules
Security / Python Security (bandit) (push) Successful in 1m50s
Test / Python Tests (pytest) (push) Successful in 1m52s
Lint / Python (flake8) (pull_request) Successful in 1m20s
Lint / Python (flake8) (push) Successful in 1m16s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / JS (eslint) (push) Successful in 15s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m5s
Test / Python Tests (pytest) (pull_request) Successful in 1m7s
Ports were keyed by their UniFi name, so when two ports shared a name the
later one replaced the earlier. The 24-port switch lost port 13 this way
(ports 13 and 14 are both "Office TV"). A repeated name is now kept as
"<name> (Port N)".

Traffic rates are now matched to the previous poll by port number rather
than name. Names are re-read from UniFi every poll, so a port renamed
there keeps its rates instead of losing them for a cycle.

Collect what UniFi reports about each SFP cage: whether a module is
present, its type (DAC or optic), part, serial, fault flags, and DOM
readings when the module has them. The faceplate draws empty cages,
optics, DACs and unidentified modules differently and outlines a faulted
module in red. The port panel gets an SFP Module section. Both ends of a
DAC report the same cable serial, so each end links to the other.

Closes #7
Closes #8

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 14:37:08 -05:00
jaredandClaude Opus 5.5 5c4e4dc099 Only trust Authelia identity headers from the proxy
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m9s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m33s
Test / Python Tests (pytest) (push) Successful in 1m54s
Lint / Python (flake8) (pull_request) Successful in 1m19s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m16s
Test / Python Tests (pytest) (pull_request) Successful in 1m29s
Remote-User/Name/Email/Groups were read from every request, so a LAN host
connecting to the container directly could claim any user and group. Add
auth.trusted_proxies and ignore those headers unless the request came from
one of them: the X-Real-IP the local nginx sets, or the peer address when
gunicorn is reached directly. With nothing configured, nobody is trusted.
Rejected attempts are logged, and /api/avatar now uses the same check.

The container's nginx site blanks the same headers for non-NPM sources
(pve-infra 4e3ab7c).

Closes #3

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 13:23:24 -05:00
jaredandClaude Opus 5.5 178a03e898 Give hosts longer before ticketing them as gone
Lint / JS (eslint) (push) Successful in 16s
Lint / Python (flake8) (push) Successful in 1m23s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m49s
Lint / Python (flake8) (pull_request) Successful in 54s
Test / Python Tests (pytest) (push) Successful in 1m35s
Lint / JS (eslint) (pull_request) Successful in 12s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m3s
A host's node_exporter stops as soon as a shutdown begins and a normal
reboot takes about 3-5 minutes, so the 2-check failure_threshold cut a
ticket for planned reboots. Add monitor.host_failure_threshold, default 5,
for hosts with no metrics and ping-only hosts. Interface link-down alerts
keep the shorter threshold, and the dashboard still shows the host as down
straight away.

Closes #14

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 19:35:50 -05:00
jaredandClaude Opus 5.5 051e70b82b Draw realistic front panels for every device model
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m7s
Lint / Python (flake8) (pull_request) Successful in 59s
Test / Python Tests (pytest) (push) Successful in 1m22s
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m7s
Test / Python Tests (pytest) (pull_request) Successful in 1m28s
Replace the port blocks on device pages with SVG faceplates traced from
reference images: Dream Machine Pro, USW Pro 24 PoE, USW Aggregation,
USW Flex, USW Flex Mini, USP PDU Pro and UPS 2U Pro. Port LEDs use each
model's documented colors, and ports show a cable or module when up.

Remove SWITCH_LAYOUTS, which had wrong data: the aggregation switch was
numbered across the rows instead of odd over even, and the USW Flex had
an SFP cage it doesn't have. Models without a faceplate use plain blocks.

Show PDU and UPS outlets with on/off state and auto power-cycle, and let
the UPS page show its panel even though it reports no ports.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 11:11:48 -05:00
jaredandClaude Opus 5.5 bdcfb76c25 Move the port inspector onto device pages
Lint / JS (eslint) (push) Successful in 1m14s
Lint / Python (flake8) (push) Successful in 2m12s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m3s
Test / Python Tests (pytest) (push) Successful in 1m11s
Lint / Python (flake8) (pull_request) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 1m5s
Replace the all-switches Inspector page with a per-device front panel,
port table and detail panel. /inspector now redirects to the dashboard,
and /device/<name>#port-<n> links directly to a port.

Restore neighbor names after UniFi's LLDP change: read local_port_idx
and resolve neighbors by MAC using Prometheus NIC data, UniFi devices
and the wired client table. This also brings back Run Diagnostics on
server ports, which depends on a named neighbor.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 10:11:11 -05:00
jaredandClaude Opus 5.5 e32499b7f6 Add AT&T modem monitoring and device pages; replace Link Debug
Lint / Python (flake8) (pull_request) Successful in 2m6s
Lint / JS (eslint) (pull_request) Successful in 18s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m20s
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 1m58s
Lint / Notify on failure (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m58s
Lint / Deploy (push) Successful in 4s
Test / Python Tests (pytest) (push) Successful in 58s
Modem and WAN:
- Poll the BGW320 status pages read-only for light levels, PON and WAN
  state, with a WAN / Fiber panel, 7-day Rx trend, and alerts on WAN down,
  optical limits, and Rx drift
- Read WAN outages and Smart Power restarts from the UniFi system log,
  since outages can be over between 5 minute polls

Device pages:
- Add device search to the dashboard and a page per host, switch, router,
  AP, PDU, or modem
- Move all Link Debug data into expandable rows there; /links redirects
- Collect UDM ports and UniFi device details (firmware, load, WAN, outlets)
- Reorder the dashboard

Monitoring fixes:
- Alert when a configured host stops reporting: its series disappear
  rather than reporting down, so a dead host never raised an alert
- Alert on Prometheus outages instead of blanking the dashboard
- Treat a failed Pulse ping as unknown rather than host unreachable
- Stop new switch ports reporting lifetime bytes as one interval's rate
- Run database sessions in UTC: other server time zones shifted displayed
  ages and timed suppression expiries

Also log every avatar 404 reason, add a favicon, and correct the WAN link
labels (1G on Port 9, not 10G SFP+).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-04 23:40:17 -05:00
jared fed279a0bd Fix false LLDP_MISMATCH: compare the switch's name with the server's lldpd neighbour
The switch port's LLDP entry describes the server, while the server's lldpctl
describes the switch, so the two were never comparable and every link with lldpd
running was flagged as cross-cabled. Pass the switch name in the port data and
compare it with the server's neighbour instead; skip the check without it.
2026-10-03 02:23:26 -04:00
jaredandClaude Sonnet 4.6 0693ad56f9 Fix monitor loop double-sleep on error; add grep -F regression test
Lint / Python (flake8) (push) Skipped
Lint / JS (eslint) (push) Skipped
On exception the monitor slept 30s inside the except block then fell
through to time.sleep(poll_interval), giving a 150s recovery gap instead
of 30s. Adding continue after the error sleep fixes this.

Also adds a regression test asserting dmesg filtering uses grep -F --
so a future refactor cannot silently reintroduce the regex wildcard bug.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-13 13:16:43 -04:00
jaredandClaude Sonnet 4.6 e0452193ee fix: flake8 E701 in avatar handler; update SSH test to match accept-new
Lint / Python (flake8) (push) Skipped
Lint / JS (eslint) (push) Skipped
- app.py: split 'with open(sentinel): pass' onto two lines (flake8 E701)
- tests/test_diagnose.py: rename test and assert StrictHostKeyChecking=accept-new (not =no which was fixed earlier)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-05-11 09:23:06 -04:00
jaredandClaude Sonnet 4.6 a5fcd619f8 test: expand diagnose test coverage — parsers, dmesg, lldp, and analyze
Add 47 new tests covering parse_ethtool_driver, parse_nic_stats,
parse_ethtool_dom (SFP DOM), parse_ip_link, parse_dmesg, parse_lldpctl,
and the analyze() health-analysis method with all issue/warning/info
code paths (NO_CARRIER, HALF_DUPLEX, SPEED_MISMATCH, SFP thresholds,
CRC errors, carrier flapping, LLDP mismatch/missing).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-25 19:53:35 -04:00
jaredandClaude Sonnet 4.6 903dc960c3 Add pytest test suite and security scanning
- Add 33 tests for DiagnosticsRunner static methods (build_ssh_command,
  parse_output, parse_sysfs_stats, parse_ethtool and variants)
- Add test.yml CI workflow running pytest on every push/PR
- Add security.yml CI workflow running bandit on every push/PR (weekly)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-14 12:22:57 -04:00