Commit Graph
28 Commits
Author SHA1 Message Date
jaredandClaude Opus 5.5 c50e1f8322 Rack: front and rear mounting, rack settings in the page
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 51s
Lint / Python (flake8) (pull_request) Successful in 55s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 52s
Test / Python Tests (pytest) (pull_request) Successful in 55s
Items are mounted from the front, the rear, or full depth. On a 4-post
rack a front and a rear item can share a unit; a full-depth one takes
both sides, and the rear view shows its back. Overlaps are checked per
side. Shelf contents take the shelf's side. A Front / Rear switch flips
the drawing.

Racks are saved in Gandalf (new cutsheet_racks table) and edited on the
rack page by admins: name, height, notes, add and delete. Renaming moves
the rack's items; saving the first rack carries over the items of the
config default it replaces. Config racks remain the fallback.

Faceplates are stretched to the full width only when the drawing is
close to the slot's proportions, so the PDU is not squashed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 22:35:37 -05:00
jaredandClaude Opus 5.5 bdd68a397d Rack: link items to devices, shelves, several racks, export; fix layout and light mode
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 48s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 49s
Lint / Python (flake8) (pull_request) Successful in 51s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 50s
Test / Python Tests (pytest) (pull_request) Successful in 53s
Cutsheet items gain a "Gandalf device" link, so an item named after the
product (UDM-Pro) shows the live device's faceplate, ports and status.
Cable checks, suggestions, tickets and the device page treat an item and
its linked device as one. Without this, product-named items drew as bare
name plates.

Items can sit on a shelf instead of a rack unit; the shelf draws what is
on it with live status. Items have a rack, the page shows a tab per rack
(config "racks"), and a rack can be downloaded as SVG or PNG.

The rack is centred, long runs of empty units fold into one band (with a
toggle), every device fills the 19" width, the UPS shows its front only,
and the rack keeps its own palette so it reads in light mode.

New cutsheet_items columns rack, shelf and device are added on first use.
Deleting a shelf, or making it something else, is refused while it holds
items; renaming it carries over.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 21:44:59 -05:00
jaredandClaude Opus 5.5 f655836446 Add a rack drawing (/rack)
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 50s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 50s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / Python (flake8) (pull_request) Successful in 52s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m2s
The rack front is drawn from the rack units on cutsheet items. Switches
with a faceplate use it, with live port state; patch panels get a generic
panel with port labels; everything else is a labelled plate. Each
documented port shows its cutsheet state, and hovering a port lights up
every port on the same cable run (through patch panels) and names the
cables. Clicking opens the switch port or the cable.

Overlapping items and items past the top of the rack are listed instead
of drawn over another; where two claim the same top unit, the first one
recorded wins. rack.units sets the height (default 42).

/api/rack builds on the cutsheet view; cutsheet.rack_layout and
cutsheet.port_marks hold the placement and per-port logic.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 20:59:30 -05:00
jaredandClaude Opus 5.5 c262e5ecc8 Inventory links, cutsheet marks on faceplates, and single page titles
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 54s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 19s
Test / Python Tests (pytest) (push) Successful in 2m6s
Security / Python Security (bandit) (pull_request) Successful in 1m18s
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 1m1s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Device pages get an Inventory button: it opens the device's HomeBox record
once an admin pastes its URL (stored in the new device_links table; only
URLs on inventory.base_url are accepted), and searches the inventory for
the model until then. Tickets link the record too.

Faceplate ports with a documented cable get a corner dot: green matches,
red mismatch, grey documented but unconfirmed. The port's tooltip names
the cable, and a legend toggle (remembered per browser) hides them.

Page titles no longer repeat GANDALF ("Alert History - GANDALF - GANDALF").

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 20:47:14 -05:00
jaredandClaude Opus 5.5 9d561db703 Add an alert history page and tie /health staleness to the poll interval
Lint / JS (eslint) (push) Successful in 6s
Lint / Python (flake8) (push) Successful in 1m56s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 2m3s
Test / Python Tests (pytest) (push) Successful in 1m0s
Lint / Python (flake8) (pull_request) Successful in 48s
Lint / JS (eslint) (pull_request) Successful in 6s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m7s
Test / Python Tests (pytest) (pull_request) Successful in 2m6s
/events lists every alert from the last 24 hours to 90 days, open or
cleared, with how long each lasted, failed checks and its ticket. Filters
(device, type, severity, state, range) live in the URL, so device pages
and tickets link straight to a device's history. A "Recurring" table
lists alerts that fired more than once on the same target. On phones the
rows become cards.

/api/events/history backs it (100 per page). The existing /api/events is
unchanged.

/health and the dashboard's monitor indicator now call the monitor
stalled after five missed polls (at least 10 minutes) instead of a fixed
20, and /health reports the monitor's age.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 20:29:09 -05:00
jaredandClaude Opus 5.5 437f7a415f Add recovery notes and fuller context to tickets
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m26s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m30s
Lint / Python (flake8) (pull_request) Successful in 52s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m28s
Test / Python Tests (pytest) (pull_request) Successful in 2m0s
When an alert that opened a ticket clears, the monitor now comments on the
ticket (when it cleared, how long it lasted, failed checks, a link back).
It never closes or changes a ticket's status. Failed notes retry each
cycle for 24 hours; a 401/403 from Tinker stops them until restart.

Tickets are now Markdown with a "What to check" list and, where known:
the switch port the device plugs into (kept from the last time it was
seen, so a dead host still shows it), cutsheet cables and their path,
how often the alert fired in the last 7/30 days, other open alerts on the
device, and links into Gandalf (gandalf.public_url). Titles are unchanged
so Tinker's duplicate detection still works.

network_events gains recovery_notified, added at monitor startup; rows
that cleared before the upgrade count as already notified.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 19:44:50 -05:00
jaredandClaude Opus 5.5 86aa29b378 Cutsheet trace mode and mismatch alerts
Lint / Python (flake8) (push) Successful in 1m8s
Security / Python Security (bandit) (push) Successful in 56s
Test / Python Tests (pytest) (push) Successful in 43s
Lint / Python (flake8) (pull_request) Successful in 50s
Lint / JS (eslint) (pull_request) Successful in 30s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 55s
Test / Python Tests (pytest) (pull_request) Successful in 50s
Lint / JS (eslint) (push) Successful in 16m17s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Trace a cord: pick a panel port, press Start, and unplug the cord at the
panel. The page polls a new admin-only endpoint that reads every switch
port's state from UniFi (cached 2 s), shows the one port that dropped
with a button to record the cable, and confirms when it's plugged back
in. Several ports dropping at once, or none within 3 minutes, is
explained rather than guessed at.

Mismatch alerts: the monitor runs the cutsheet check every poll. Each
mismatched installed run (wrong neighbor, no link, missing port, port
conflict) keeps one cable_mismatch event on its switch, resolved when
fixed, and opens a P4 ticket after cutsheet.mismatch_ticket_hours
(default 24, 0 never). Suppressing the switch or port stops the ticket.

Also fixes buttons with the hidden attribute still showing, which left a
Delete button on the new-cable form.

Closes #12

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 16:54:57 -05:00
jaredandClaude Opus 5.5 b9412ff6ba Add cutsheets: planned cabling checked against discovery
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m36s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m40s
Lint / Python (flake8) (pull_request) Successful in 52s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m13s
Test / Python Tests (pytest) (pull_request) Successful in 1m15s
A new Cutsheet page records where every cable is meant to go and compares
it with what Gandalf discovers.

- Inventory for what discovery can't see: patch panels, wall jacks,
  shelves and rack positions. Panels and jacks pass through front to rear.
- Cables with two endpoints, ID, type, length, color, status (planned,
  installed, dark, retired) and notes; the far end may be unterminated.
- Each cable's full run is traced through panels and jacks, and runs
  ending on a switch port are checked against its discovered neighbor
  (LLDP, client table, or a DAC serial seen at both ends): matches,
  wrong neighbor, no link, missing port, port conflict, unverified, idle.
- Undocumented links: live switch ports no cable mentions, one click to
  add with what Gandalf already knows. Port panels show the planned cable.
- Labels to make: cable IDs and panel-port labels not yet applied, with a
  print view, for a handheld label maker.
- CSV export, and all-or-nothing import that upserts by cable ID.
- Cables, panels and jacks appear in the dashboard search.

Editing needs the admin group and a JSON request body. Every change is
written to cutsheet_history in the same transaction. Tables are created
on first use.

Refs #12

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 16:05:08 -05:00
jaredandClaude Opus 5.5 7e588e5b02 Keep every switch port and show SFP modules
Security / Python Security (bandit) (push) Successful in 1m50s
Test / Python Tests (pytest) (push) Successful in 1m52s
Lint / Python (flake8) (pull_request) Successful in 1m20s
Lint / Python (flake8) (push) Successful in 1m16s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / JS (eslint) (push) Successful in 15s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m5s
Test / Python Tests (pytest) (pull_request) Successful in 1m7s
Ports were keyed by their UniFi name, so when two ports shared a name the
later one replaced the earlier. The 24-port switch lost port 13 this way
(ports 13 and 14 are both "Office TV"). A repeated name is now kept as
"<name> (Port N)".

Traffic rates are now matched to the previous poll by port number rather
than name. Names are re-read from UniFi every poll, so a port renamed
there keeps its rates instead of losing them for a cycle.

Collect what UniFi reports about each SFP cage: whether a module is
present, its type (DAC or optic), part, serial, fault flags, and DOM
readings when the module has them. The faceplate draws empty cages,
optics, DACs and unidentified modules differently and outlines a faulted
module in red. The port panel gets an SFP Module section. Both ends of a
DAC report the same cable serial, so each end links to the other.

Closes #7
Closes #8

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 14:37:08 -05:00
jaredandClaude Opus 5.5 5c4e4dc099 Only trust Authelia identity headers from the proxy
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m9s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m33s
Test / Python Tests (pytest) (push) Successful in 1m54s
Lint / Python (flake8) (pull_request) Successful in 1m19s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m16s
Test / Python Tests (pytest) (pull_request) Successful in 1m29s
Remote-User/Name/Email/Groups were read from every request, so a LAN host
connecting to the container directly could claim any user and group. Add
auth.trusted_proxies and ignore those headers unless the request came from
one of them: the X-Real-IP the local nginx sets, or the peer address when
gunicorn is reached directly. With nothing configured, nobody is trusted.
Rejected attempts are logged, and /api/avatar now uses the same check.

The container's nginx site blanks the same headers for non-NPM sources
(pve-infra 4e3ab7c).

Closes #3

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 13:23:24 -05:00
jaredandClaude Opus 5.5 178a03e898 Give hosts longer before ticketing them as gone
Lint / JS (eslint) (push) Successful in 16s
Lint / Python (flake8) (push) Successful in 1m23s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m49s
Lint / Python (flake8) (pull_request) Successful in 54s
Test / Python Tests (pytest) (push) Successful in 1m35s
Lint / JS (eslint) (pull_request) Successful in 12s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m3s
A host's node_exporter stops as soon as a shutdown begins and a normal
reboot takes about 3-5 minutes, so the 2-check failure_threshold cut a
ticket for planned reboots. Add monitor.host_failure_threshold, default 5,
for hosts with no metrics and ping-only hosts. Interface link-down alerts
keep the shorter threshold, and the dashboard still shows the host as down
straight away.

Closes #14

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 19:35:50 -05:00
jaredandClaude Opus 5.5 051e70b82b Draw realistic front panels for every device model
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m7s
Lint / Python (flake8) (pull_request) Successful in 59s
Test / Python Tests (pytest) (push) Successful in 1m22s
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m7s
Test / Python Tests (pytest) (pull_request) Successful in 1m28s
Replace the port blocks on device pages with SVG faceplates traced from
reference images: Dream Machine Pro, USW Pro 24 PoE, USW Aggregation,
USW Flex, USW Flex Mini, USP PDU Pro and UPS 2U Pro. Port LEDs use each
model's documented colors, and ports show a cable or module when up.

Remove SWITCH_LAYOUTS, which had wrong data: the aggregation switch was
numbered across the rows instead of odd over even, and the USW Flex had
an SFP cage it doesn't have. Models without a faceplate use plain blocks.

Show PDU and UPS outlets with on/off state and auto power-cycle, and let
the UPS page show its panel even though it reports no ports.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 11:11:48 -05:00
jaredandClaude Opus 5.5 bdcfb76c25 Move the port inspector onto device pages
Lint / JS (eslint) (push) Successful in 1m14s
Lint / Python (flake8) (push) Successful in 2m12s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m3s
Test / Python Tests (pytest) (push) Successful in 1m11s
Lint / Python (flake8) (pull_request) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 1m5s
Replace the all-switches Inspector page with a per-device front panel,
port table and detail panel. /inspector now redirects to the dashboard,
and /device/<name>#port-<n> links directly to a port.

Restore neighbor names after UniFi's LLDP change: read local_port_idx
and resolve neighbors by MAC using Prometheus NIC data, UniFi devices
and the wired client table. This also brings back Run Diagnostics on
server ports, which depends on a named neighbor.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 10:11:11 -05:00
jaredandClaude Opus 5.5 e32499b7f6 Add AT&T modem monitoring and device pages; replace Link Debug
Lint / Python (flake8) (pull_request) Successful in 2m6s
Lint / JS (eslint) (pull_request) Successful in 18s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m20s
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 1m58s
Lint / Notify on failure (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m58s
Lint / Deploy (push) Successful in 4s
Test / Python Tests (pytest) (push) Successful in 58s
Modem and WAN:
- Poll the BGW320 status pages read-only for light levels, PON and WAN
  state, with a WAN / Fiber panel, 7-day Rx trend, and alerts on WAN down,
  optical limits, and Rx drift
- Read WAN outages and Smart Power restarts from the UniFi system log,
  since outages can be over between 5 minute polls

Device pages:
- Add device search to the dashboard and a page per host, switch, router,
  AP, PDU, or modem
- Move all Link Debug data into expandable rows there; /links redirects
- Collect UDM ports and UniFi device details (firmware, load, WAN, outlets)
- Reorder the dashboard

Monitoring fixes:
- Alert when a configured host stops reporting: its series disappear
  rather than reporting down, so a dead host never raised an alert
- Alert on Prometheus outages instead of blanking the dashboard
- Treat a failed Pulse ping as unknown rather than host unreachable
- Stop new switch ports reporting lifetime bytes as one interval's rate
- Run database sessions in UTC: other server time zones shifted displayed
  ages and timed suppression expiries

Also log every avatar 404 reason, add a favicon, and correct the WAN link
labels (1G on Port 9, not 10G SFP+).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-04 23:40:17 -05:00
jared 4a1998046b README: add walkthrough GIF, rationale and gallery; add demo seed, mock PULSE and capture scripts
Lint / Python (flake8) (push) Failing after 2m9s
Lint / JS (eslint) (push) Successful in 11s
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 39s
Test / Python Tests (pytest) (push) Successful in 40s
Lint / Notify on failure (push) Successful in 3s
2026-10-03 02:23:26 -04:00
jaredandClaude Sonnet 5 42cf754796 Add separate unifi_failure_threshold to avoid false tickets on reboots
Lint / Python (flake8) (push) Failing after 1m4s
Lint / JS (eslint) (push) Successful in 5s
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Failing after 37s
Test / Python Tests (pytest) (push) Failing after 33s
Lint / Notify on failure (push) Successful in 2s
UniFi switches/APs take several minutes to rejoin after a firmware-update
reboot (observed AP taking 12 min on the scheduled 3am update), longer than
the 2-consecutive-check (~4 min) threshold shared with host link-down
detection. Give UniFi device offline detection its own, more forgiving
threshold so momentary maintenance reboots don't cut tickets.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UB2D82eYNzD1bnMHhFPjRr
2026-09-04 20:59:43 -04:00
jaredandClaude Sonnet 4.6 0d4f792a46 Add CI badges and CI/CD section to README
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-14 12:53:47 -04:00
jaredandClaude Sonnet 4.6 bc1d3fb33b Remove aesthetic_diff.md reference from README — convergence complete
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-14 21:50:02 -04:00
jaredandClaude Sonnet 4.6 fb6848b7e0 Apply LotusGuild design system convergence (aesthetic_diff.md)
CSS (style.css):
- §1: Add unified naming aliases (--terminal-green, --bg-primary, etc.)
- §2: Upgrade borders: modal 1px→3px double, btn/btn-sm/inputs 1px→2px
- §3: Add [ ] bracket decorations to .btn classes; primary keeps > prefix;
  hover lift -1px→-2px; padding 6px 14px→5px 12px
- §4: Fix glow definitions from 2-layer rgba to 3-layer solid stack
- §5: Section headers now symmetric ╠═══ TITLE ═══╣ (was one-sided)
- §6+§7: Modal border 3px double, corners ┌┐→╔╗, add glow shadow
- §11: Nav active state now amber tint (was green); hover remains green
- §15: Scanline opacity 0.13→0.15; flicker delay 45s→30s

JS (app.js):
- §18: Replace custom showToast() with lt.toast.* delegate wrapper

Templates (base.html):
- Load base.css and base.js (symlinked from web_template)
- Add lt-boot overlay for boot sequence animation (§13)

README: Remove completed pending convergence items

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-14 21:40:20 -04:00
jaredandClaude Sonnet 4.6 468dbda7a1 feat: inspector page, link debug enhancements, security hardening
- Add /inspector page: visual model-accurate switch chassis diagrams
  (USF5P, USL8A, US24PRO, USPPDUP, USMINI), clickable port blocks
  with color coding (green=up, amber=PoE, cyan=uplink, grey=down),
  detail panel with stats/PoE/LLDP, LLDP-based path debug side-by-side

- Link Debug: port number badges (#N), LLDP neighbor line, PoE class/max,
  collapsible host/switch panels with sessionStorage persistence

- monitor.py: collect LLDP neighbor map + PoE class/max/mode per switch
  port; PulseClient uses requests.Session() for HTTP keep-alive; add
  shlex.quote() around interface names (defense-in-depth)

- Security: suppress buttons use data-* attrs + delegated click handler
  instead of inline onclick with Jinja2 variable interpolation; remove
  | safe filter from user-controlled fields in suppressions.html;
  setDuration() takes explicit el param instead of implicit event global

- db.py: thread-local connection reuse with ping(reconnect=True) to
  avoid a new TCP handshake per query

- .gitignore: add config.json (contains credentials), __pycache__

- README: full rewrite covering architecture, all 4 pages, alert logic,
  config reference, deployment, troubleshooting, security notes

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-03 15:39:48 -05:00
jared 124a8c4ea2 chore: remove deploy test line from README 2026-03-02 12:08:16 -05:00
jared 565bd4ee24 chore: test auto-deploy pipeline 2026-03-02 12:05:59 -05:00
jared 150300ff91 chore: clean up deploy test line from README 2026-03-02 12:00:46 -05:00
jared 997c626c3c chore: trigger deploy test 2026-03-02 11:58:42 -05:00
jaredandClaude Sonnet 4.6 c201604dca docs: update README for storage-01 Prometheus migration
- storage-01 now monitored via Prometheus node_exporter (10.10.10.11:9100),
  removed from ping_hosts
- Updated data sources table (6 hosts via Prometheus, pbs only via ping)
- Added storage-01 to monitored hosts table
- Fixed Authelia reload command (restart, not reload)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-01 23:05:27 -05:00
jaredandClaude Sonnet 4.6 04a5182259 Complete rewrite: full-featured network monitoring dashboard
- Two-service architecture: Flask web app (gandalf.service) + background
  polling daemon (gandalf-monitor.service)
- Monitor polls Prometheus node_network_up for physical NIC states on all
  6 hypervisors (added storage-01 at 10.10.10.11:9100)
- UniFi API monitoring for switches, APs, and gateway device status
- Ping reachability for hosts without node_exporter (pbs only now)
- Smart baseline: interfaces first seen as down are never alerted on;
  only UP→DOWN regressions trigger tickets
- Cluster-wide P1 ticket when 3+ hosts have genuine simultaneous
  interface regressions (guards against false positives on startup)
- Tinker Tickets integration with 24-hour hash-based deduplication
- Alert suppression: manual toggle or timed windows (30m/1h/4h/8h)
- Authelia SSO via forward-auth headers, admin group required
- Network topology: Internet → UDM-Pro → Agg Switch (10G DAC) →
  PoE Switch (10G DAC) → Hosts
- MariaDB schema, suppression management UI, host/interface cards

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-01 23:03:18 -05:00
jared 109dff1cd0 test 2025-01-04 00:33:04 -05:00
jared a746140e8b first commit 2025-01-04 00:07:15 -05:00