Files
gandalf/README.md
T
jaredandClaude Opus 5.5 e32499b7f6
Lint / Python (flake8) (pull_request) Successful in 2m6s
Lint / JS (eslint) (pull_request) Successful in 18s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m20s
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 1m58s
Lint / Notify on failure (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m58s
Lint / Deploy (push) Successful in 4s
Test / Python Tests (pytest) (push) Successful in 58s
Add AT&T modem monitoring and device pages; replace Link Debug
Modem and WAN:
- Poll the BGW320 status pages read-only for light levels, PON and WAN
  state, with a WAN / Fiber panel, 7-day Rx trend, and alerts on WAN down,
  optical limits, and Rx drift
- Read WAN outages and Smart Power restarts from the UniFi system log,
  since outages can be over between 5 minute polls

Device pages:
- Add device search to the dashboard and a page per host, switch, router,
  AP, PDU, or modem
- Move all Link Debug data into expandable rows there; /links redirects
- Collect UDM ports and UniFi device details (firmware, load, WAN, outlets)
- Reorder the dashboard

Monitoring fixes:
- Alert when a configured host stops reporting: its series disappear
  rather than reporting down, so a dead host never raised an alert
- Alert on Prometheus outages instead of blanking the dashboard
- Treat a failed Pulse ping as unknown rather than host unreachable
- Stop new switch ports reporting lifetime bytes as one interval's rate
- Run database sessions in UTC: other server time zones shifted displayed
  ages and timed suppression expiries

Also log every avatar 404 reason, add a favicon, and correct the WAN link
labels (1G on Port 9, not 10G SFP+).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-04 23:40:17 -05:00

27 KiB
Raw Blame History

GANDALF (Global Advanced Network Detection And Link Facilitator)

Lint Test Security

Because it shall not let problems pass.

Network monitoring dashboard for the LotusGuild Proxmox cluster. Deployed on LXC 157 (monitor-02 / 10.10.10.9), reachable at gandalf.lotusguild.org.

Design System: web_template — shared CSS, JS, and layout patterns for all LotusGuild apps

GANDALF walkthrough: dashboard, link debug with optical readings, switch inspector, and a one-click link diagnostic

Why this exists

A Proxmox/Ceph cluster lives or dies by its network, and network problems are sneaky: a link that flaps, a fibre with weak receive power, a switch port that quietly negotiated 1 Gbps. GANDALF watches the cluster's links from three angles at once (host NIC state from Prometheus, switch ports and LLDP from the UniFi controller, and reachability pings), alerts only on regressions (a link that was up and went down; ports that were never connected are learned as baseline and ignored), and files one ticket per real problem. When something looks wrong, a click on the switch port runs a full on-host diagnostic through PULSE (ethtool, SFP optics, kernel log, LLDP) and explains what it found.

Dashboard: alert queue with linked tickets, a live topology, per-host interface status and the UniFi device inventory.

Dashboard

Topology diagram

Host cards

Device pages: search by hostname, IP, MAC, model or interface from the dashboard, then open one page per host, switch, router, PDU or modem. Each interface or port is one row with its state, speed, traffic and neighbour. Expanding a row shows duplex, carrier flaps, error and drop rates, PoE, LLDP, and SFP optical readings (temperature, TX/RX power) with colour-coded thresholds.

Network inspector: chassis diagrams for each UniFi switch. Click a port for its stats, LLDP neighbour and a side-by-side switch/server path check.

Inspector

One-click diagnostics: GANDALF asks a PULSE worker to SSH to the host on the other end of the link and collect everything in one pass, then analyzes it: carrier, duplex and speed mismatches, SFP power levels, CRC errors, link flaps, recent kernel events and LLDP validation.

Diagnostics

Suppressions: timed or manual maintenance windows per host, interface or UniFi device, with a full history.

Suppressions

Light theme:

Dashboard, light theme

Screenshots come from a throwaway local instance seeded with fictional data (documentation IP ranges), with PULSE replaced by a small mock. See scripts/demo/.

Styling & Layout

GANDALF uses the LotusGuild Terminal Design System. For all styling, component, and layout documentation see:


Architecture

Two processes share a MariaDB database:

Process Service Role
app.py gandalf.service Flask web dashboard (gunicorn, port 8000)
monitor.py gandalf-monitor.service Background polling daemon
[Prometheus :9090]  ──▶
[UniFi Controller]  ──▶  monitor.py ──▶ MariaDB ◀── app.py ──▶ nginx ──▶ Authelia ──▶ Browser
[Pulse Worker]      ──▶
[SSH / ethtool]     ──▶
[AT&T BGW320]       ──▶

Data Sources

Source What it provides
Prometheus (10.10.10.48:9090) Physical NIC link state + traffic/error rates via node_exporter
UniFi API (https://10.10.10.1) Switch port stats, device status, LLDP neighbor table, PoE data
Pulse Worker SSH relay — runs ethtool + SFP DOM queries on each Proxmox host
Ping Reachability for hosts without node_exporter (e.g. PBS)
AT&T BGW320 (http://192.168.1.254) Fiber light levels, PON and WAN state, WAN counters, scraped read-only from the gateway's status pages (no login)

Monitored Hosts (Prometheus / node_exporter)

Host Prometheus Instance
large1 10.10.10.2:9100
compute-storage-01 10.10.10.4:9100
micro1 10.10.10.8:9100
monitor-02 10.10.10.9:9100
compute-storage-gpu-01 10.10.10.10:9100
storage-01 10.10.10.11:9100

Ping-only (no node_exporter): pbs (10.10.10.3)


Pages

Dashboard (/)

  • Device search (see Device pages below)
  • Active alerts first, then the WAN / Fiber panel, hosts, UniFi devices, topology, and recently resolved alerts
  • Real-time host status grid with per-NIC link state (UP / DOWN / degraded)
  • Network topology diagram (Internet → Modem → Gateway → Switches → Hosts)
  • WAN / Fiber panel: WAN and PON state, Rx/Tx power, optics temperature, throughput, errors, gateway uptime and last restart, 7-day Rx trend, recent WAN outages
  • UniFi device table (switches, APs, gateway)
  • Active alerts table with severity, target, consecutive failures, ticket link
  • Quick-suppress modal: apply timed or manual suppression from any alert row
  • Auto-refreshes every 30 seconds via /api/status + /api/network

Device pages (/device/<name>)

One page per host, switch, router, AP, PDU, or modem. Reach them from the search box on the dashboard (/ focuses it), or from any device name. Search matches hostname, IP, MAC, model, type, interface and port names, and LLDP neighbors.

  • Overview: status, IP, MAC, model, firmware, uptime, CPU, memory, clients, temperatures, power draw
  • Alerts: active and past alerts for this device
  • WAN (routers): connection state, speed, latency, availability
  • Connected to (hosts): switch ports that see this host over LLDP
  • Outlets (PDUs): per-outlet state, power, and auto power-cycle setting
  • Interfaces / Ports: one row each with state, speed, RX/TX rate, and neighbor, filterable. Expanding a row shows duplex, auto-negotiation, carrier changes, error and drop rates, traffic bars, PoE, LLDP detail, and the SFP / optical panel (vendor/PN, temperature, voltage, bias, TX/RX power, RX−TX delta)
  • WAN / Fiber (modem): the same panel as the dashboard

These replaced the Link Debug page; /links now redirects to the dashboard. Hosts that Prometheus sees but config.json doesn't list still get a page, with their state shown as unknown because they aren't alerted on.

Inspector (/inspector)

Visual switch chassis diagrams. Each switch is rendered model-accurately using layout config in the template (SWITCH_LAYOUTS).

Port block colours:

Colour State
Green Up, no active PoE
Amber Up with active PoE draw
Cyan Uplink port (up)
Grey Down
White outline Currently selected

Clicking a port opens the right-side detail panel showing:

  • Link stats (status, speed, duplex, auto-neg, media type)
  • PoE (class, max wattage, current draw, mode)
  • Traffic (TX/RX rates)
  • Errors/drops per second
  • LLDP Neighbor section (system name, port ID, chassis ID, management IPs)
  • Path Debug (auto-appears when LLDP system_name matches a known server): two-column comparison of the switch port stats vs. the server NIC stats, including SFP DOM data if the server side has an SFP module

LLDP path debug requirements:

  1. Server must run lldpd: apt install lldpd && systemctl enable --now lldpd
  2. lldpd hostname must match the key in data.hosts (set via config.json → hosts)
  3. Switch has LLDP enabled (UniFi default: on)

Supported switch models (set SWITCH_LAYOUTS keys to your UniFi model codes):

Key Model Layout
USF5P UniFi Switch Flex 5 PoE 4×RJ45 + 1×SFP uplink
USL8A UniFi Switch Lite 8 PoE 8×SFP (2 rows of 4)
US24PRO UniFi Switch Pro 24 24×RJ45 staggered + 2×SFP
USPPDUP Custom/other Single-port fallback
UDMPRO Dream Machine Pro 9×RJ45 + 2×SFP+
USMINI UniFi Switch Mini 5-port row

Add new layouts by adding a key to SWITCH_LAYOUTS matching the model field returned by the UniFi API for that device.

Suppressions (/suppressions)

  • Create timed (30 min / 1 hr / 4 hr / 8 hr) or manual suppressions
  • Target types: host, interface, UniFi device, or global
  • Active suppressions table with one-click removal
  • Suppression history (last 50)
  • Available targets reference grid (all known hosts + interfaces)

Alert Logic

Ticket Triggers

Condition Priority
UniFi device offline (≥unifi_failure_threshold consecutive checks) P2 High
Proxmox host NIC link-down regression (≥2 consecutive checks) P2 High
Host unreachable via ping (≥2 consecutive checks) P2 High
Configured host has no metrics in Prometheus (host or node_exporter down, ≥2 consecutive checks) P2 High
Prometheus unavailable, so host and interface alerting is paused (≥2 consecutive checks) P2 High
≥3 hosts simultaneously reporting interface or metrics failures P1 Critical
WAN down: broadband or optical status not Up, or PON not in O5 (≥modem.failure_threshold) P1 Critical
Modem not responding (≥modem.failure_threshold) P2 High
Fiber Rx/Tx power or optics temperature in the module's alarm range, or a supply voltage or Tx bias alarm flag (≥modem.failure_threshold) P2 High
Fiber reading in the module's warning range (≥modem.failure_threshold) P3
Rx power rx_drift_db or more below its 7-day median (≥modem.failure_threshold) P3
Modem pages unreadable, e.g. after a firmware update (≥modem.failure_threshold) P3
UniFi logs that Smart Power auto power-cycled the modem P3
UniFi logs that the WAN failed multiple times in 24 hours (at most one ticket a day) P2

A failed Pulse ping check counts as "unknown": it neither raises nor resolves host_unreachable.

WAN modem notes

The alarm and warning limits are read from the gateway on every poll, so they are never hard-coded here. Those limits are wide (warning at -27.9 dBm on a link that normally sits near -17), so fiber_rx_drift compares each reading to the link's own 7-day median to catch a damaged connector earlier. It stays quiet until rx_drift_min_samples readings exist (about a day at a 5 minute poll).

Outages can be over between polls: two real ones lasted about two minutes against a 5 minute poll. So WAN outages and modem restarts also come from the UniFi system log, and a drop in the modem's uptime records a restart even if nothing logged it. A single short outage only appears in the panel's history.

To silence modem alerts during maintenance, create a host suppression with the modem's name.

Baseline Tracking

Interfaces that are down on first observation (unused ports, unplugged cables) are recorded as initial_down and never alerted. Only UP→DOWN regressions generate tickets. Baseline is stored in MariaDB and survives daemon restarts.

Suppression Targets

Type Suppresses
host All interface alerts for a named host
interface A specific NIC on a specific host
unifi_device A specific UniFi device
all Everything (global maintenance mode)

Suppressions can be manual (persist until removed) or timed (auto-expire). Expired suppressions are checked at evaluation time — no background cleanup needed.


Configuration (config.json)

Shared by both processes. Located in the working directory (/var/www/html/prod/).

{
  "database": {
    "host": "10.10.10.50",
    "port": 3306,
    "user": "gandalf",
    "password": "...",
    "name": "gandalf"
  },
  "prometheus": {
    "url": "http://10.10.10.48:9090"
  },
  "unifi": {
    "controller": "https://10.10.10.1",
    "api_key": "...",
    "site_id": "default"
  },
  "ticket_api": {
    "url": "https://t.lotusguild.org/api/tickets",
    "api_key": "..."
  },
  "pulse": {
    "url": "http://<pulse-host>:<port>",
    "api_key": "...",
    "worker_id": "...",
    "timeout": 45
  },
  "auth": {
    "allowed_groups": ["admin"]
  },
  "hosts": [
    { "name": "large1",               "prometheus_instance": "10.10.10.2:9100" },
    { "name": "compute-storage-01",   "prometheus_instance": "10.10.10.4:9100" },
    { "name": "micro1",               "prometheus_instance": "10.10.10.8:9100" },
    { "name": "monitor-02",           "prometheus_instance": "10.10.10.9:9100" },
    { "name": "compute-storage-gpu-01", "prometheus_instance": "10.10.10.10:9100" },
    { "name": "storage-01",           "prometheus_instance": "10.10.10.11:9100" }
  ],
  "monitor": {
    "poll_interval": 120,
    "failure_threshold": 2,
    "unifi_failure_threshold": 5,
    "cluster_threshold": 3,
    "ping_hosts": [
      { "name": "pbs", "ip": "10.10.10.3" }
    ]
  },
  "modem": {
    "url": "http://192.168.1.254",
    "name": "att-modem"
  }
}

Key Config Fields

Key Description
database.* MariaDB credentials (LXC 149 at 10.10.10.50)
prometheus.url Prometheus base URL
unifi.controller UniFi controller base URL (HTTPS, self-signed cert ignored)
unifi.api_key UniFi API key from controller Settings → API
unifi.site_id UniFi site ID (default: default)
ticket_api.api_key Tinker Tickets bearer token
pulse.url Pulse worker API base URL (for SSH relay)
pulse.worker_id Which Pulse worker runs ethtool collection
pulse.timeout Max seconds to wait for SSH collection per host
auth.allowed_groups Authelia groups that may access Gandalf
hosts Maps Prometheus instance labels → display hostnames
monitor.poll_interval Seconds between full check cycles (default: 120)
monitor.failure_threshold Consecutive failures before creating ticket (default: 2)
monitor.unifi_failure_threshold Consecutive failures before ticketing a UniFi device as offline (default: same as failure_threshold). Set higher than failure_threshold — UniFi switches/APs can take several minutes to rejoin after a firmware-update reboot, so a low threshold cuts tickets for momentary maintenance reboots instead of real failures.
monitor.cluster_threshold Hosts with failures to trigger cluster-wide P1 (default: 3)
monitor.ping_hosts Hosts checked only by ping (no node_exporter)
modem.url AT&T gateway base URL. Omit the modem block to disable modem monitoring. Must be reachable from the monitor host.
modem.name Name used for the modem's alerts, tickets, and suppressions (default: att-modem)
modem.timeout Seconds to wait per status page (default: 10)
modem.failure_threshold Consecutive failures before ticketing a modem alert (default: same as failure_threshold). Raise it if gateway reboots or automatic firmware updates cut tickets.
modem.rx_drift_db Rx drop below the 7-day median that raises fiber_rx_drift (default: 3.0)
modem.rx_drift_min_samples Readings required before drift alerts start (default: 288)

Deployment (LXC 157)

1. Database — MariaDB LXC 149 (10.10.10.50)

CREATE DATABASE gandalf CHARACTER SET utf8mb4 COLLATE utf8mb4_unicode_ci;
CREATE USER 'gandalf'@'10.10.10.61' IDENTIFIED BY 'your_password';
GRANT ALL PRIVILEGES ON gandalf.* TO 'gandalf'@'10.10.10.61';
FLUSH PRIVILEGES;

Import schema:

mysql -h 10.10.10.50 -u gandalf -p gandalf < schema.sql

2. LXC 157 — Install dependencies

pip3 install -r requirements.txt
# Ensure sshpass is available (used by deploy scripts)
apt install sshpass

3. Deploy files

# From dev machine / root/code/gandalf:
for f in app.py db.py monitor.py config.json schema.sql \
          static/style.css static/app.js \
          templates/*.html; do
  sshpass -p 'yourpass' scp -o StrictHostKeyChecking=no \
    "$f" "root@10.10.10.61:/var/www/html/prod/$f"
done
systemctl restart gandalf gandalf-monitor

4. systemd services

gandalf.service (Flask/gunicorn web app):

[Unit]
Description=Gandalf Web Dashboard
After=network.target

[Service]
Type=simple
WorkingDirectory=/var/www/html/prod
ExecStart=/usr/bin/python3 -m gunicorn --workers 1 --bind 127.0.0.1:8000 app:app
Restart=always

[Install]
WantedBy=multi-user.target

gandalf-monitor.service (background polling daemon):

[Unit]
Description=Gandalf Network Monitor Daemon
After=network.target

[Service]
Type=simple
WorkingDirectory=/var/www/html/prod
ExecStart=/usr/bin/python3 monitor.py
Restart=always

[Install]
WantedBy=multi-user.target

5. Authelia rule (LXC 167)

access_control:
  rules:
    - domain: gandalf.lotusguild.org
      policy: one_factor
      subject:
        - group:admin
systemctl restart authelia

6. NPM reverse proxy

  • Domain: gandalf.lotusguild.org
  • Forward to: http://10.10.10.61:8000 (gunicorn direct, no nginx needed on LXC)
  • Forward Auth: Authelia at http://10.10.10.167:9091
  • WebSockets: Not required

Service Management

# Status
systemctl status gandalf gandalf-monitor

# Logs (live)
journalctl -u gandalf -f
journalctl -u gandalf-monitor -f

# Restart after code or config changes
systemctl restart gandalf gandalf-monitor

Troubleshooting

Avatar photo missing (/api/avatar returns 404)

journalctl -u gandalf | grep -i avatar gives the reason: no ldap.host / ldap.bind_dn (missing config), ldap3 not installed (run pip3 install -r requirements.txt), LDAP avatar lookup failed (bind or network), LDAP has no photo (or Remote-User doesn't match a uid), or a cached no photo marker, which expires after ldap.cache_ttl seconds or can be removed from ldap.cache_dir.

Monitor not creating tickets

  • Verify config.json → ticket_api.api_key is set and valid
  • Check journalctl -u gandalf-monitor for Ticket creation failed lines
  • Confirm the Tinker Tickets API is reachable from LXC 157

WAN / Fiber panel missing or showing "unavailable"

  • The panel stays hidden until config.json → modem.url is set and the monitor has completed a cycle
  • Test from the monitor host: curl -s -o /dev/null -w '%{http_code}\n' http://192.168.1.254/cgi-bin/fiberstat.ha should print 200
  • modem_data_invalid means the gateway answered but its pages couldn't be parsed. AT&T updates firmware automatically, so compare the page against the parsers in modem.py (markup confirmed on BGW320-505 firmware 6.35.8)

Device pages show no interface data

  • Check gandalf-monitor.service is running and has completed at least one cycle
  • Check journalctl -u gandalf-monitor for Prometheus or UniFi errors
  • Verify Prometheus is reachable: curl http://10.10.10.48:9090/api/v1/query?query=up

Device page: SFP / optical panel missing

  • SFP data requires Pulse worker + SSH access to hosts
  • Verify config.json → pulse.* is configured and the Pulse worker is running
  • Confirm sshpass + SSH access from the Pulse worker to each Proxmox host
  • Only interfaces with physical SFP modules return DOM data (ethtool -m)

Inspector: path debug section not appearing

  • Requires LLDP: run apt install lldpd && systemctl enable --now lldpd on each server
  • The LLDP system_name broadcast by lldpd must match the hostname in config.json → hosts[].name
    • Override: echo 'configure system hostname large1' > /etc/lldpd.d/hostname.conf && systemctl restart lldpd
  • Allow up to 2 poll cycles (240s) after installing lldpd for LLDP table to populate

Inspector: switch chassis shows as flat list (no layout)

  • The switch's model field from UniFi doesn't match any key in SWITCH_LAYOUTS in inspector.html
  • Check the UniFi API: the model appears in the link_stats API response under unifi_switches.<name>.model
  • Add the model key to SWITCH_LAYOUTS in inspector.html with the correct row/SFP layout

Baseline re-initializing on every restart

  • interface_baseline is stored in the monitor_state DB table; survives restarts
  • If it appears to reset: check DB connectivity from the monitor daemon

Interface stuck at "initial_down" forever

  • This means the interface was down when the monitor first saw it
  • It will begin tracking once it comes up; or manually clear it:
    -- In MariaDB on 10.10.10.50:
    UPDATE monitor_state SET value='{}' WHERE key_name='interface_baseline';
    
    Then restart the monitor: systemctl restart gandalf-monitor

Prometheus data missing for a host

# On the affected host:
systemctl status prometheus-node-exporter
# Verify it's scraped:
curl http://10.10.10.48:9090/api/v1/query?query=up | jq '.data.result[] | select(.metric.job=="node")'

Development Notes

File Layout

gandalf/
├── app.py              # Flask web app (routes, auth, API endpoints)
├── monitor.py          # Background daemon (Prometheus, UniFi, Pulse, alert logic)
├── modem.py            # Read-only AT&T gateway status page client and parser
├── devices.py          # Device inventory for search and device pages
├── db.py               # Database operations (MariaDB via pymysql, thread-local conn reuse)
├── schema.sql          # Database schema (network_events, suppression_rules, monitor_state)
├── config.json         # Runtime configuration (not committed with secrets)
├── requirements.txt    # Python dependencies
├── static/
│   ├── style.css       # Terminal aesthetic CSS (CRT scanlines, green-on-black)
│   ├── app.js          # Dashboard JS (auto-refresh, events, suppress modal, search, modem panel)
│   └── device.js       # Device page rendering
└── templates/
    ├── base.html       # Shared layout (header, nav, footer)
    ├── index.html      # Dashboard page
    ├── device.html     # Per-device page
    ├── _modem_panel.html # WAN / Fiber panel, shared by the dashboard and modem page
    ├── inspector.html  # Visual switch inspector + LLDP path debug
    └── suppressions.html # Suppression management page

Adding a New Monitored Host

  1. Install prometheus-node-exporter on the host
  2. Add a scrape target to Prometheus config
  3. Add an entry to config.json → hosts:
    { "name": "newhost", "prometheus_instance": "10.10.10.X:9100" }
    
  4. Restart monitor: systemctl restart gandalf-monitor
  5. For SFP DOM / ethtool: ensure the host is SSH-accessible from the Pulse worker

Adding a New Switch Layout (Inspector)

Find the UniFi model code for the switch (it appears in the /api/links JSON response under unifi_switches.<switch_name>.model), then add to SWITCH_LAYOUTS in templates/inspector.html:

'MYNEWMODEL': {
  rows: [[1,2,3,4,5,6,7,8], [9,10,11,12,13,14,15,16]],  // port_idx by row
  sfp_section: [17, 18],  // separate SFP cage ports (rendered below rows)
  sfp_ports: [],          // port_idx values that are SFP-type within rows
},

Database Schema Notes

  • network_events: one row per active event; resolved_at is set when recovered
  • suppression_rules: active=FALSE when removed; expires_at checked at query time
  • monitor_state: key/value store; interface_baseline, link_stats, and modem_stats are JSON blobs
  • monitor_state also holds wan_history (WAN outages, modem restarts) and unifi_log_cursor (how far the UniFi log has been read)
  • Database sessions run in UTC (db.py), whatever the server's time zone
  • modem_samples: optical readings per poll, kept 90 days; created automatically at monitor startup

Security Notes

  • XSS prevention: all user-controlled data in dynamically generated HTML uses escHtml() (JS) or Jinja2 auto-escaping (Python). Suppress buttons use data-* attributes + a single delegated click listener rather than inline onclick with interpolated strings.
  • Interface name validation: monitor.py validates SSH interface names against ^[a-zA-Z0-9_.@-]+$ before use, and additionally wraps them with shlex.quote() for defense-in-depth.
  • DB parameters: all SQL uses parameterised queries via pymysql — no string concatenation into SQL.
  • Auth: Authelia enforces admin-only access at the nginx/LXC 167 layer; the Flask app additionally checks the Remote-User header via @require_auth.

Known Limitations

  • Single gunicorn worker (--workers 1) — required because db.py uses thread-local connection reuse (one connection per thread). Multiple workers would each have their own connection, which is fine, but the thread-local optimisation only helps within one worker.
  • No CSRF tokens on API endpoints — mitigated by Authelia session cookies being SameSite=Strict and the site being admin-only.
  • SSH collection via Pulse is synchronous — if Pulse is slow, the entire monitor cycle is delayed. The pulse.timeout config controls the max wait.
  • UniFi LLDP data is only as fresh as the last monitor poll (120s default).

CI / CD

Workflow Purpose Triggers
lint.yml (python-lint) flake8 on all .py files Every push and PR
lint.yml (js-lint) ESLint on static/ Every push and PR
test.yml pytest — diagnose.py, modem.py, and monitor.py alert logic Every push and PR
security.yml bandit -ll (medium+ severity) Every push, PR, and weekly Monday 6am
deploy job in lint.yml Calls the gandalf-deploy webhook on CT157 (10.10.10.61) Push to main only, after both lint jobs pass

Branch protection is enabled on main — both lint jobs must pass before any PR can merge.

Tests live in tests/:

  • test_diagnose.py: DiagnosticsRunner static methods (build_ssh_command, parse_output, parse_sysfs_stats, parse_ethtool, and variants)
  • test_modem.py: gateway page parsing, optical status, and WAN state
  • test_monitor.py: alert logic for dead hosts, Prometheus and Pulse outages, and modem and WAN log events
  • test_devices.py: device inventory behind search and device pages