README: patch panel ends, tap to trace, stale outlet watts, SmartPower Strip
Lint / JS (eslint) (push) Successful in 8s
Lint / Python (flake8) (push) Successful in 1m21s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m45s
Test / Python Tests (pytest) (push) Successful in 2m24s
Lint / Python (flake8) (pull_request) Successful in 2m14s
Lint / JS (eslint) (pull_request) Successful in 9s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m56s
Test / Python Tests (pytest) (pull_request) Successful in 2m0s
Lint / JS (eslint) (push) Successful in 8s
Lint / Python (flake8) (push) Successful in 1m21s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m45s
Test / Python Tests (pytest) (push) Successful in 2m24s
Lint / Python (flake8) (pull_request) Successful in 2m14s
Lint / JS (eslint) (pull_request) Successful in 9s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m56s
Test / Python Tests (pytest) (pull_request) Successful in 2m0s
Documents #41 and #42 in the Topology and Device pages sections and the faceplate list, and refreshes the topology gallery image (patch panel end and the new strip drawing). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -206,7 +206,10 @@ servers along the bottom. Power gear (PDU, UPS, power strip) sits in a rail on t
|
||||
- **Unknown devices**: something plugged into a switch port that Gandalf can't name is a grey stub,
|
||||
labelled with the port name (or its address), linking to that port. By default each switch's unknown
|
||||
devices are one block with one bundled cable ("10 unknown devices"); click it to show them one by
|
||||
one, or pick "one by one" or "hidden" in the toolbar.
|
||||
one, or pick "one by one" or "hidden" in the toolbar. When the cutsheet records the cable going into
|
||||
a patch panel, the far end is drawn as that panel's 24 jacks with the cable on its documented port,
|
||||
named "Patch panel port 1" (the device beyond the panel is unknown); a stub that already has a name
|
||||
keeps it and adds "via Patch panel port 2". The cable details show where the cutsheet cable goes.
|
||||
- **Port names**: a ⚠ marks a port named after one device with a different one plugged in (a port
|
||||
called "Large1 Management" with the AP on it). Generic names ("Port 4", "SFP+ 2", "Uplink") and
|
||||
"Downlink to X" with X on the other end never flag.
|
||||
@@ -214,16 +217,24 @@ servers along the bottom. Power gear (PDU, UPS, power strip) sits in a rail on t
|
||||
severity colour, and the NIC it is about is marked.
|
||||
- **Power**: each PDU, UPS and power strip card lists its outlets that feed something, draw power or
|
||||
are off, with live watts; each device it feeds shows a ⚡ badge with what it draws. Hover a power
|
||||
card or a device to draw its feeds. An outlet that is off but feeds something is listed above the
|
||||
card or a device to draw its feeds. The SmartPower Strip has no metering, so it never shows watts. An outlet that is off but feeds something is listed above the
|
||||
diagram. What an outlet feeds comes from, in order: an assignment saved here, the outlet's name in
|
||||
UniFi when it names a device ("storage-01", "Dream Machine Pro", "AT&T Modem" for the modem), or a
|
||||
MAC in its name that belongs to a host NIC or UniFi device. Admins click an outlet to set what it
|
||||
feeds, set it to nothing, or go back to automatic. Assignments are kept in Gandalf (table
|
||||
`power_feeds`); Gandalf never renames outlets in UniFi. API: `PUT /api/topology/power/<device>/<outlet>`
|
||||
with `{"target": "<device>"}`, `""` for nothing or `null` for automatic.
|
||||
- **Stale outlet watts**: UniFi can keep serving one frozen set of USP PDU Pro outlet readings for hours
|
||||
while the unit's total stays live. When a unit's loaded outlets have not changed at all for 15 minutes,
|
||||
the monitor marks them stale: the outlet rows say "stale" instead of watts, ⚡ badges say "fed", and
|
||||
the list above the diagram says since when (`outlets_stale_since` in `link_stats.unifi_devices`). The
|
||||
marks clear on the next poll after the readings move. The 15 minutes start again when the monitor
|
||||
restarts. Restarting the PDU or updating its firmware in UniFi is the usual cure.
|
||||
- Click a device for its page, or a port on a faceplate for that port. Click a cable for its details:
|
||||
both ends, speed, cable type and module, traffic each way and how busy it is, errors and drops, and
|
||||
its cutsheet record. Hovering a device traces its path to the internet.
|
||||
its cutsheet record. Hovering a device traces its path to the internet. On a touch screen, which
|
||||
has no hover, the first tap on a device traces it (path and power feeds) and a second tap opens it;
|
||||
tapping empty canvas clears it.
|
||||
- Drag to pan, scroll or pinch to zoom, **Fit** (or `0`) to see everything, `+` and `-` to zoom. Show
|
||||
unknown devices grouped, one by one or not at all. **Server 1G links** (off by default) adds each
|
||||
server's slower second cable, its management link; **Power gear** shows or hides the power rail. Traffic labels and dimming everything without an alert can be switched too. The
|
||||
@@ -245,7 +256,8 @@ interface and port names, and LLDP neighbors.
|
||||
- **Alerts**: active and past alerts for this device
|
||||
- **WAN** (routers): connection state, speed, latency, availability
|
||||
- **Connected to** (hosts): switch ports that see this host over LLDP
|
||||
- **Outlets** (PDUs): per-outlet state, power, and auto power-cycle setting
|
||||
- **Outlets** (PDUs, UPS, power strip): per-outlet state, power, and auto power-cycle setting; readings
|
||||
UniFi has frozen are marked stale (see Topology)
|
||||
- **Port inspector** (switches, routers): see below
|
||||
- **Interfaces / Ports**: one row each with state, speed, RX/TX rate, and neighbor, filterable.
|
||||
Expanding a host's row shows duplex, auto-negotiation, carrier changes, error and drop rates,
|
||||
@@ -318,6 +330,7 @@ neighbors that can't be matched show their MAC. Bonded NICs share a MAC, so only
|
||||
| `USMINI` | USW Flex Mini | 5×RJ45, PoE in on port 1 |
|
||||
| `USPPDUP` | USP PDU Pro | 20 outlets (4 USB-C, 16 AC), management port 21, surge pass-through ports 22-23 |
|
||||
| `USPDA2B` | UPS 2U Pro | Front with touchscreen outlet tiles; rear with 8 outlets, EPO, surge and MGMT ports |
|
||||
| `UP6` | SmartPower Strip | Top face: 6 AC outlets in facing pairs, 4 USB-C (switched together as outlet 7) |
|
||||
|
||||
Port LEDs use the colors from each model's quick start guide. Other models use plain blocks until they get an
|
||||
entry in `FACEPLATES`.
|
||||
@@ -833,6 +846,7 @@ gandalf/
|
||||
|
||||
UniFi gear drawn with live ports: UDM Pro (`UDMPRO`), USW Pro 24 PoE (`US24PRO`), USW Aggregation
|
||||
(`USL8A`), USW Flex (`USF5P`), USW Flex Mini (`USMINI`), USP PDU Pro (`USPPDUP`), UPS 2U Pro (`USPDA2B`),
|
||||
SmartPower Strip (`UP6`, outlets only),
|
||||
USW Pro Max 24 PoE (`USPM24P`, also `USPM24`) and USW Pro Max 48 PoE (`USPM48P`, also `USPM48`), plus the
|
||||
UniFi NVR Pro (`UNVRPRO`), which UniFi Network doesn't report and so is picked by Front drawing. The Pro
|
||||
Max switches also have Front drawing options, so a new switch draws correctly on the rack before it is
|
||||
|
||||
Binary file not shown.
|
Before Width: | Height: | Size: 163 KiB After Width: | Height: | Size: 161 KiB |
Reference in New Issue