Add storage-01 HBA bay 5 mapping (phy9)

Verified via ls -la /dev/disk/by-path/ and physical inspection
that HBA SAS3416 phy9 maps to bay 5 (C0 SATA breakout).
Remaining C0 bays 6-8 and C1 bays 9-10 still need drives to verify.

Ref #25

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
2026-02-06 18:20:44 -05:00
parent 2177ae9092
commit 4a98a6f6f8

View File

@@ -529,14 +529,17 @@ declare -A SERVER_MAPPINGS=(
# C1: 4x SATA breakout → bays 9-10 (2 of 4 ports used)
# C2: U.2 NVMe (serial ends in 0d66) → u2-1
# C3: U.2 NVMe (serial ends in 0d4f) → u2-2
# NOTE: HBA PHY-to-bay mapping needs verification via ls -la /dev/disk/by-path/
# NOTE: U.2 drives require HBA firmware update to appear
# C0 verified: phy9=bay5 (remaining phy8/10/11 → bays 6-8 TBD)
# C1: PHY-to-bay mapping TBD (bays 9-10)
# C2: U.2 NVMe (serial ends in 0d66) → u2-1 (needs FW update)
# C3: U.2 NVMe (serial ends in 0d4f) → u2-2 (needs FW update)
# Also present: 09:00.0 AMD FCH SATA Controller [AHCI mode]
["storage-01"]="
pci-0000:02:00.1-ata-1 1
pci-0000:02:00.1-ata-2 2
pci-0000:02:00.1-ata-5 3
pci-0000:02:00.1-ata-6 4
pci-0000:01:00.0-sas-phy9-lun-0 5
"
# large1