UniFi Smart Power on the RPDU's modem outlet saw the internet down while the modem rebooted and cut its power mid-boot: once during the 11-20 restart and twice after the 11-24 AT&T-app reboot. UniFi only exposes auto power-cycle as on or off, so the button now turns it off for every outlet that has it on, and the monitor turns it back on when the restart ends (back, or after 30 minutes). - UnifiClient.auto_power_cycle_outlets / set_auto_power_cycle: sends the device's outlet_overrides back with only cycle_enabled changed, then reads them again to confirm. The only UniFi setting Gandalf changes. - A failed pause doesn't stop the restart; a failed restart turns it back on. A failed restore is retried every cycle and shown as broken in Needs attention until it works. - The panel note and confirm text mention the pause. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>