Restart modem: pause Smart Power auto power-cycle until the modem is back
UniFi Smart Power on the RPDU's modem outlet saw the internet down while
the modem rebooted and cut its power mid-boot: once during the 11-20
restart and twice after the 11-24 AT&T-app reboot. UniFi only exposes
auto power-cycle as on or off, so the button now turns it off for every
outlet that has it on, and the monitor turns it back on when the restart
ends (back, or after 30 minutes).

- UnifiClient.auto_power_cycle_outlets / set_auto_power_cycle: sends the
  device's outlet_overrides back with only cycle_enabled changed, then
  reads them again to confirm. The only UniFi setting Gandalf changes.
- A failed pause doesn't stop the restart; a failed restart turns it back
  on. A failed restore is retried every cycle and shown as broken in
  Needs attention until it works.
- The panel note and confirm text mention the pause.