Topology: power map, what each outlet feeds
- Each PDU, UPS and power strip card lists its outlets that feed
  something, draw power or are off, with live watts. Each device fed
  gets a power badge with what it draws. Hovering a power card or a
  device draws its feeds as dotted lines and keeps both ends lit.
- What an outlet feeds: a saved assignment, else the outlet's UniFi name
  when it names a device (or the modem), else a MAC in its name that
  belongs to a host NIC (the monitor's host_macs) or UniFi device.
- Admins click an outlet to set what it feeds, nothing, or automatic.
  Saved in a new power_feeds table (created with the cutsheet tables);
  PUT /api/topology/power/<device>/<outlet>, admin and JSON only, with
  the device, outlet and target checked. UniFi is never changed.
- An outlet that is off but feeds something is listed under "to look at".
- Power gear is shown by default again, now that it has something to say.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-14 20:28:13 -05:00
..
2026-11-11 17:19:45 -05:00
2026-11-11 17:19:45 -05:00