Lint / JS (eslint) (push) Successful in 12s
Lint / Python (flake8) (push) Successful in 1m47s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m15s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Python (flake8) (pull_request) Successful in 48s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Test / Python Tests (pytest) (push) Successful in 1m41s
Security / Python Security (bandit) (pull_request) Successful in 1m32s
Test / Python Tests (pytest) (pull_request) Successful in 1m6s
#31 treated any open interface_down alert as previously up. Production had six such alerts all created in the same second on 2026-03-02 (a monitor glitch, on ports that were never in use: large1 enp36s0 and a USB adapter, compute-storage-01 nic1-3, micro1 enp3s0). Reviving them opened per-host tickets and a P1 cluster-wide ticket. Back to the previous behaviour while a safer fix is worked out. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>