Commit Graph
6 Commits
Author SHA1 Message Date
jaredandClaude Opus 5.5 86aa29b378 Cutsheet trace mode and mismatch alerts
Lint / Python (flake8) (push) Successful in 1m8s
Security / Python Security (bandit) (push) Successful in 56s
Test / Python Tests (pytest) (push) Successful in 43s
Lint / Python (flake8) (pull_request) Successful in 50s
Lint / JS (eslint) (pull_request) Successful in 30s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 55s
Test / Python Tests (pytest) (pull_request) Successful in 50s
Lint / JS (eslint) (push) Successful in 16m17s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Trace a cord: pick a panel port, press Start, and unplug the cord at the
panel. The page polls a new admin-only endpoint that reads every switch
port's state from UniFi (cached 2 s), shows the one port that dropped
with a button to record the cable, and confirms when it's plugged back
in. Several ports dropping at once, or none within 3 minutes, is
explained rather than guessed at.

Mismatch alerts: the monitor runs the cutsheet check every poll. Each
mismatched installed run (wrong neighbor, no link, missing port, port
conflict) keeps one cable_mismatch event on its switch, resolved when
fixed, and opens a P4 ticket after cutsheet.mismatch_ticket_hours
(default 24, 0 never). Suppressing the switch or port stops the ticket.

Also fixes buttons with the hidden attribute still showing, which left a
Delete button on the new-cable form.

Closes #12

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 16:54:57 -05:00
jaredandClaude Opus 5.5 b9412ff6ba Add cutsheets: planned cabling checked against discovery
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m36s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m40s
Lint / Python (flake8) (pull_request) Successful in 52s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m13s
Test / Python Tests (pytest) (pull_request) Successful in 1m15s
A new Cutsheet page records where every cable is meant to go and compares
it with what Gandalf discovers.

- Inventory for what discovery can't see: patch panels, wall jacks,
  shelves and rack positions. Panels and jacks pass through front to rear.
- Cables with two endpoints, ID, type, length, color, status (planned,
  installed, dark, retired) and notes; the far end may be unterminated.
- Each cable's full run is traced through panels and jacks, and runs
  ending on a switch port are checked against its discovered neighbor
  (LLDP, client table, or a DAC serial seen at both ends): matches,
  wrong neighbor, no link, missing port, port conflict, unverified, idle.
- Undocumented links: live switch ports no cable mentions, one click to
  add with what Gandalf already knows. Port panels show the planned cable.
- Labels to make: cable IDs and panel-port labels not yet applied, with a
  print view, for a handheld label maker.
- CSV export, and all-or-nothing import that upserts by cable ID.
- Cables, panels and jacks appear in the dashboard search.

Editing needs the admin group and a JSON request body. Every change is
written to cutsheet_history in the same transaction. Tables are created
on first use.

Refs #12

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 16:05:08 -05:00
jaredandClaude Opus 5.5 5c4e4dc099 Only trust Authelia identity headers from the proxy
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m9s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m33s
Test / Python Tests (pytest) (push) Successful in 1m54s
Lint / Python (flake8) (pull_request) Successful in 1m19s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m16s
Test / Python Tests (pytest) (pull_request) Successful in 1m29s
Remote-User/Name/Email/Groups were read from every request, so a LAN host
connecting to the container directly could claim any user and group. Add
auth.trusted_proxies and ignore those headers unless the request came from
one of them: the X-Real-IP the local nginx sets, or the peer address when
gunicorn is reached directly. With nothing configured, nobody is trusted.
Rejected attempts are logged, and /api/avatar now uses the same check.

The container's nginx site blanks the same headers for non-NPM sources
(pve-infra 4e3ab7c).

Closes #3

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 13:23:24 -05:00
jaredandClaude Opus 5.5 051e70b82b Draw realistic front panels for every device model
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m7s
Lint / Python (flake8) (pull_request) Successful in 59s
Test / Python Tests (pytest) (push) Successful in 1m22s
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m7s
Test / Python Tests (pytest) (pull_request) Successful in 1m28s
Replace the port blocks on device pages with SVG faceplates traced from
reference images: Dream Machine Pro, USW Pro 24 PoE, USW Aggregation,
USW Flex, USW Flex Mini, USP PDU Pro and UPS 2U Pro. Port LEDs use each
model's documented colors, and ports show a cable or module when up.

Remove SWITCH_LAYOUTS, which had wrong data: the aggregation switch was
numbered across the rows instead of odd over even, and the USW Flex had
an SFP cage it doesn't have. Models without a faceplate use plain blocks.

Show PDU and UPS outlets with on/off state and auto power-cycle, and let
the UPS page show its panel even though it reports no ports.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 11:11:48 -05:00
jaredandClaude Opus 5.5 bdcfb76c25 Move the port inspector onto device pages
Lint / JS (eslint) (push) Successful in 1m14s
Lint / Python (flake8) (push) Successful in 2m12s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m3s
Test / Python Tests (pytest) (push) Successful in 1m11s
Lint / Python (flake8) (pull_request) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 1m5s
Replace the all-switches Inspector page with a per-device front panel,
port table and detail panel. /inspector now redirects to the dashboard,
and /device/<name>#port-<n> links directly to a port.

Restore neighbor names after UniFi's LLDP change: read local_port_idx
and resolve neighbors by MAC using Prometheus NIC data, UniFi devices
and the wired client table. This also brings back Run Diagnostics on
server ports, which depends on a named neighbor.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 10:11:11 -05:00
jaredandClaude Opus 5.5 e32499b7f6 Add AT&T modem monitoring and device pages; replace Link Debug
Lint / Python (flake8) (pull_request) Successful in 2m6s
Lint / JS (eslint) (pull_request) Successful in 18s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m20s
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 1m58s
Lint / Notify on failure (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m58s
Lint / Deploy (push) Successful in 4s
Test / Python Tests (pytest) (push) Successful in 58s
Modem and WAN:
- Poll the BGW320 status pages read-only for light levels, PON and WAN
  state, with a WAN / Fiber panel, 7-day Rx trend, and alerts on WAN down,
  optical limits, and Rx drift
- Read WAN outages and Smart Power restarts from the UniFi system log,
  since outages can be over between 5 minute polls

Device pages:
- Add device search to the dashboard and a page per host, switch, router,
  AP, PDU, or modem
- Move all Link Debug data into expandable rows there; /links redirects
- Collect UDM ports and UniFi device details (firmware, load, WAN, outlets)
- Reorder the dashboard

Monitoring fixes:
- Alert when a configured host stops reporting: its series disappear
  rather than reporting down, so a dead host never raised an alert
- Alert on Prometheus outages instead of blanking the dashboard
- Treat a failed Pulse ping as unknown rather than host unreachable
- Stop new switch ports reporting lifetime bytes as one interval's rate
- Run database sessions in UTC: other server time zones shifted displayed
  ages and timed suppression expiries

Also log every avatar 404 reason, add a favicon, and correct the WAN link
labels (1G on Port 9, not 10G SFP+).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-04 23:40:17 -05:00