Commit Graph
4 Commits
Author SHA1 Message Date
jaredandClaude Opus 5.5 7e588e5b02 Keep every switch port and show SFP modules
Security / Python Security (bandit) (push) Successful in 1m50s
Test / Python Tests (pytest) (push) Successful in 1m52s
Lint / Python (flake8) (pull_request) Successful in 1m20s
Lint / Python (flake8) (push) Successful in 1m16s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / JS (eslint) (push) Successful in 15s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m5s
Test / Python Tests (pytest) (pull_request) Successful in 1m7s
Ports were keyed by their UniFi name, so when two ports shared a name the
later one replaced the earlier. The 24-port switch lost port 13 this way
(ports 13 and 14 are both "Office TV"). A repeated name is now kept as
"<name> (Port N)".

Traffic rates are now matched to the previous poll by port number rather
than name. Names are re-read from UniFi every poll, so a port renamed
there keeps its rates instead of losing them for a cycle.

Collect what UniFi reports about each SFP cage: whether a module is
present, its type (DAC or optic), part, serial, fault flags, and DOM
readings when the module has them. The faceplate draws empty cages,
optics, DACs and unidentified modules differently and outlines a faulted
module in red. The port panel gets an SFP Module section. Both ends of a
DAC report the same cable serial, so each end links to the other.

Closes #7
Closes #8

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-10 14:37:08 -05:00
jaredandClaude Opus 5.5 178a03e898 Give hosts longer before ticketing them as gone
Lint / JS (eslint) (push) Successful in 16s
Lint / Python (flake8) (push) Successful in 1m23s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m49s
Lint / Python (flake8) (pull_request) Successful in 54s
Test / Python Tests (pytest) (push) Successful in 1m35s
Lint / JS (eslint) (pull_request) Successful in 12s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m3s
A host's node_exporter stops as soon as a shutdown begins and a normal
reboot takes about 3-5 minutes, so the 2-check failure_threshold cut a
ticket for planned reboots. Add monitor.host_failure_threshold, default 5,
for hosts with no metrics and ping-only hosts. Interface link-down alerts
keep the shorter threshold, and the dashboard still shows the host as down
straight away.

Closes #14

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-06 19:35:50 -05:00
jaredandClaude Opus 5.5 bdcfb76c25 Move the port inspector onto device pages
Lint / JS (eslint) (push) Successful in 1m14s
Lint / Python (flake8) (push) Successful in 2m12s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m3s
Test / Python Tests (pytest) (push) Successful in 1m11s
Lint / Python (flake8) (pull_request) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 1m5s
Replace the all-switches Inspector page with a per-device front panel,
port table and detail panel. /inspector now redirects to the dashboard,
and /device/<name>#port-<n> links directly to a port.

Restore neighbor names after UniFi's LLDP change: read local_port_idx
and resolve neighbors by MAC using Prometheus NIC data, UniFi devices
and the wired client table. This also brings back Run Diagnostics on
server ports, which depends on a named neighbor.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-05 10:11:11 -05:00
jaredandClaude Opus 5.5 e32499b7f6 Add AT&T modem monitoring and device pages; replace Link Debug
Lint / Python (flake8) (pull_request) Successful in 2m6s
Lint / JS (eslint) (pull_request) Successful in 18s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m20s
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 1m58s
Lint / Notify on failure (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m58s
Lint / Deploy (push) Successful in 4s
Test / Python Tests (pytest) (push) Successful in 58s
Modem and WAN:
- Poll the BGW320 status pages read-only for light levels, PON and WAN
  state, with a WAN / Fiber panel, 7-day Rx trend, and alerts on WAN down,
  optical limits, and Rx drift
- Read WAN outages and Smart Power restarts from the UniFi system log,
  since outages can be over between 5 minute polls

Device pages:
- Add device search to the dashboard and a page per host, switch, router,
  AP, PDU, or modem
- Move all Link Debug data into expandable rows there; /links redirects
- Collect UDM ports and UniFi device details (firmware, load, WAN, outlets)
- Reorder the dashboard

Monitoring fixes:
- Alert when a configured host stops reporting: its series disappear
  rather than reporting down, so a dead host never raised an alert
- Alert on Prometheus outages instead of blanking the dashboard
- Treat a failed Pulse ping as unknown rather than host unreachable
- Stop new switch ports reporting lifetime bytes as one interval's rate
- Run database sessions in UTC: other server time zones shifted displayed
  ages and timed suppression expiries

Also log every avatar 404 reason, add a favicon, and correct the WAN link
labels (1G on Port 9, not 10G SFP+).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>