Ports were keyed by their UniFi name, so when two ports shared a name the
later one replaced the earlier. The 24-port switch lost port 13 this way
(ports 13 and 14 are both "Office TV"). A repeated name is now kept as
"<name> (Port N)".
Traffic rates are now matched to the previous poll by port number rather
than name. Names are re-read from UniFi every poll, so a port renamed
there keeps its rates instead of losing them for a cycle.
Collect what UniFi reports about each SFP cage: whether a module is
present, its type (DAC or optic), part, serial, fault flags, and DOM
readings when the module has them. The faceplate draws empty cages,
optics, DACs and unidentified modules differently and outlines a faulted
module in red. The port panel gets an SFP Module section. Both ends of a
DAC report the same cable serial, so each end links to the other.
Closes#7Closes#8
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Replace the port blocks on device pages with SVG faceplates traced from
reference images: Dream Machine Pro, USW Pro 24 PoE, USW Aggregation,
USW Flex, USW Flex Mini, USP PDU Pro and UPS 2U Pro. Port LEDs use each
model's documented colors, and ports show a cable or module when up.
Remove SWITCH_LAYOUTS, which had wrong data: the aggregation switch was
numbered across the rows instead of odd over even, and the USW Flex had
an SFP cage it doesn't have. Models without a faceplate use plain blocks.
Show PDU and UPS outlets with on/off state and auto power-cycle, and let
the UPS page show its panel even though it reports no ports.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>