rack-drawn-fronts
6
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
3c9e5fd593 |
Faceplates: model labels as printed on the units
Lint / JS (eslint) (push) Successful in 16s
Lint / Python (flake8) (push) Successful in 1m6s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Python (flake8) (pull_request) Successful in 52s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 53s
Security / Python Security (bandit) (push) Successful in 54s
Test / Python Tests (pytest) (push) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m16s
The label under each UniFi screen was one weight, left-aligned, and on the UDM read "Dream Machine Pro". Checked against the NetBox reference photos (and the UDM against the real unit), the labels are now centred under the screen with the first word bold and the rest light: "UDM Pro", "USW Pro" with its PoE mark, "USW", "NVR Pro", "USP PDU Pro". One helper (fpModel) draws them all, so the NVR no longer looks bolder than the switches. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
565fdd81de |
Rack: NVR Pro as a real faceplate; Sliger and Rosewill touch-ups
Lint / JS (eslint) (push) Successful in 18s
Security / Python Security (bandit) (push) Successful in 1m45s
Lint / Python (flake8) (push) Successful in 1m25s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Python (flake8) (pull_request) Successful in 52s
Lint / JS (eslint) (pull_request) Successful in 6s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Test / Python Tests (pytest) (push) Successful in 1m18s
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 53s
The hand-drawn NVR Pro didn't match the UniFi faceplates: flat colours, low contrast and its own port shapes. It is now a FACEPLATES entry (UNVRPRO) built from the same parts as the UDM Pro: metal body, RJ45 jack, SFP+ cage, quad screen, vents and labels. Front drawing "UniFi NVR Pro" uses it, and it would go live if UniFi ever reports the model. Sliger bays are numbered 1-10 (driveAtlas's order); the Rosewill door is perforated with a latch. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
bdd68a397d |
Rack: link items to devices, shelves, several racks, export; fix layout and light mode
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 48s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 49s
Lint / Python (flake8) (pull_request) Successful in 51s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 50s
Test / Python Tests (pytest) (pull_request) Successful in 53s
Cutsheet items gain a "Gandalf device" link, so an item named after the product (UDM-Pro) shows the live device's faceplate, ports and status. Cable checks, suggestions, tickets and the device page treat an item and its linked device as one. Without this, product-named items drew as bare name plates. Items can sit on a shelf instead of a rack unit; the shelf draws what is on it with live status. Items have a rack, the page shows a tab per rack (config "racks"), and a rack can be downloaded as SVG or PNG. The rack is centred, long runs of empty units fold into one band (with a toggle), every device fills the 19" width, the UPS shows its front only, and the rack keeps its own palette so it reads in light mode. New cutsheet_items columns rack, shelf and device are added on first use. Deleting a shelf, or making it something else, is refused while it holds items; renaming it carries over. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c262e5ecc8 |
Inventory links, cutsheet marks on faceplates, and single page titles
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 54s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 19s
Test / Python Tests (pytest) (push) Successful in 2m6s
Security / Python Security (bandit) (pull_request) Successful in 1m18s
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 1m1s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Device pages get an Inventory button: it opens the device's HomeBox record
once an admin pastes its URL (stored in the new device_links table; only
URLs on inventory.base_url are accepted), and searches the inventory for
the model until then. Tickets link the record too.
Faceplate ports with a documented cable get a corner dot: green matches,
red mismatch, grey documented but unconfirmed. The port's tooltip names
the cable, and a legend toggle (remembered per browser) hides them.
Page titles no longer repeat GANDALF ("Alert History - GANDALF - GANDALF").
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
7e588e5b02 |
Keep every switch port and show SFP modules
Security / Python Security (bandit) (push) Successful in 1m50s
Test / Python Tests (pytest) (push) Successful in 1m52s
Lint / Python (flake8) (pull_request) Successful in 1m20s
Lint / Python (flake8) (push) Successful in 1m16s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / JS (eslint) (push) Successful in 15s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m5s
Test / Python Tests (pytest) (pull_request) Successful in 1m7s
Ports were keyed by their UniFi name, so when two ports shared a name the later one replaced the earlier. The 24-port switch lost port 13 this way (ports 13 and 14 are both "Office TV"). A repeated name is now kept as "<name> (Port N)". Traffic rates are now matched to the previous poll by port number rather than name. Names are re-read from UniFi every poll, so a port renamed there keeps its rates instead of losing them for a cycle. Collect what UniFi reports about each SFP cage: whether a module is present, its type (DAC or optic), part, serial, fault flags, and DOM readings when the module has them. The faceplate draws empty cages, optics, DACs and unidentified modules differently and outlines a faulted module in red. The port panel gets an SFP Module section. Both ends of a DAC report the same cable serial, so each end links to the other. Closes #7 Closes #8 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
051e70b82b |
Draw realistic front panels for every device model
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m7s
Lint / Python (flake8) (pull_request) Successful in 59s
Test / Python Tests (pytest) (push) Successful in 1m22s
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m7s
Test / Python Tests (pytest) (pull_request) Successful in 1m28s
Replace the port blocks on device pages with SVG faceplates traced from reference images: Dream Machine Pro, USW Pro 24 PoE, USW Aggregation, USW Flex, USW Flex Mini, USP PDU Pro and UPS 2U Pro. Port LEDs use each model's documented colors, and ports show a cable or module when up. Remove SWITCH_LAYOUTS, which had wrong data: the aggregation switch was numbered across the rows instead of odd over even, and the USW Flex had an SFP cage it doesn't have. Models without a faceplate use plain blocks. Show PDU and UPS outlets with on/off state and auto power-cycle, and let the UPS page show its panel even though it reports no ports. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |