pro-max-faceplates
13
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
619a2c913d |
Remove em and en dashes from the UI, code and docs
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 57s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Python (flake8) (pull_request) Successful in 51s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m0s
Test / Python Tests (pytest) (push) Successful in 1m3s
Test / Python Tests (pytest) (pull_request) Successful in 52s
Page titles read "Rack | GANDALF", ranges use a hyphen (U26-42, 1-100 of 300), empty cells show "-", and dash-separated phrases use a colon, comma or full stop. In the shared base.js only the on-screen strings changed (boot line, placeholders, offline banner and toast). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
0f4e129c20 |
Rack: drawn fronts for the NVR and server cases
Lint / JS (eslint) (push) Successful in 15s
Security / Python Security (bandit) (push) Successful in 1m5s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (push) Successful in 1m0s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 57s
Items Gandalf has no live faceplate for can pick a Front drawing: the UniFi NVR Pro (drawn from the CC0 NetBox devicetype-library image), the Sliger CX4712 4U and Rosewill RSV-L4500U 4U cases (from driveAtlas's layouts), and generic 1U/2U/4U servers. The power light shows the linked device's live status. They export with the rest of the rack. New cutsheet_items column chassis, added on first use. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c50e1f8322 |
Rack: front and rear mounting, rack settings in the page
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 51s
Lint / Python (flake8) (pull_request) Successful in 55s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 52s
Test / Python Tests (pytest) (pull_request) Successful in 55s
Items are mounted from the front, the rear, or full depth. On a 4-post rack a front and a rear item can share a unit; a full-depth one takes both sides, and the rear view shows its back. Overlaps are checked per side. Shelf contents take the shelf's side. A Front / Rear switch flips the drawing. Racks are saved in Gandalf (new cutsheet_racks table) and edited on the rack page by admins: name, height, notes, add and delete. Renaming moves the rack's items; saving the first rack carries over the items of the config default it replaces. Config racks remain the fallback. Faceplates are stretched to the full width only when the drawing is close to the slot's proportions, so the PDU is not squashed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
bdd68a397d |
Rack: link items to devices, shelves, several racks, export; fix layout and light mode
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 48s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 49s
Lint / Python (flake8) (pull_request) Successful in 51s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 50s
Test / Python Tests (pytest) (pull_request) Successful in 53s
Cutsheet items gain a "Gandalf device" link, so an item named after the product (UDM-Pro) shows the live device's faceplate, ports and status. Cable checks, suggestions, tickets and the device page treat an item and its linked device as one. Without this, product-named items drew as bare name plates. Items can sit on a shelf instead of a rack unit; the shelf draws what is on it with live status. Items have a rack, the page shows a tab per rack (config "racks"), and a rack can be downloaded as SVG or PNG. The rack is centred, long runs of empty units fold into one band (with a toggle), every device fills the 19" width, the UPS shows its front only, and the rack keeps its own palette so it reads in light mode. New cutsheet_items columns rack, shelf and device are added on first use. Deleting a shelf, or making it something else, is refused while it holds items; renaming it carries over. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
f655836446 |
Add a rack drawing (/rack)
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 50s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 50s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / Python (flake8) (pull_request) Successful in 52s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m2s
The rack front is drawn from the rack units on cutsheet items. Switches with a faceplate use it, with live port state; patch panels get a generic panel with port labels; everything else is a labelled plate. Each documented port shows its cutsheet state, and hovering a port lights up every port on the same cable run (through patch panels) and names the cables. Clicking opens the switch port or the cable. Overlapping items and items past the top of the rack are listed instead of drawn over another; where two claim the same top unit, the first one recorded wins. rack.units sets the height (default 42). /api/rack builds on the cutsheet view; cutsheet.rack_layout and cutsheet.port_marks hold the placement and per-port logic. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c262e5ecc8 |
Inventory links, cutsheet marks on faceplates, and single page titles
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 54s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 19s
Test / Python Tests (pytest) (push) Successful in 2m6s
Security / Python Security (bandit) (pull_request) Successful in 1m18s
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 1m1s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Device pages get an Inventory button: it opens the device's HomeBox record
once an admin pastes its URL (stored in the new device_links table; only
URLs on inventory.base_url are accepted), and searches the inventory for
the model until then. Tickets link the record too.
Faceplate ports with a documented cable get a corner dot: green matches,
red mismatch, grey documented but unconfirmed. The port's tooltip names
the cable, and a legend toggle (remembered per browser) hides them.
Page titles no longer repeat GANDALF ("Alert History - GANDALF - GANDALF").
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
||
|
|
9d561db703 |
Add an alert history page and tie /health staleness to the poll interval
Lint / JS (eslint) (push) Successful in 6s
Lint / Python (flake8) (push) Successful in 1m56s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 2m3s
Test / Python Tests (pytest) (push) Successful in 1m0s
Lint / Python (flake8) (pull_request) Successful in 48s
Lint / JS (eslint) (pull_request) Successful in 6s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m7s
Test / Python Tests (pytest) (pull_request) Successful in 2m6s
/events lists every alert from the last 24 hours to 90 days, open or cleared, with how long each lasted, failed checks and its ticket. Filters (device, type, severity, state, range) live in the URL, so device pages and tickets link straight to a device's history. A "Recurring" table lists alerts that fired more than once on the same target. On phones the rows become cards. /api/events/history backs it (100 per page). The existing /api/events is unchanged. /health and the dashboard's monitor indicator now call the monitor stalled after five missed polls (at least 10 minutes) instead of a fixed 20, and /health reports the monitor's age. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
86aa29b378 |
Cutsheet trace mode and mismatch alerts
Lint / Python (flake8) (push) Successful in 1m8s
Security / Python Security (bandit) (push) Successful in 56s
Test / Python Tests (pytest) (push) Successful in 43s
Lint / Python (flake8) (pull_request) Successful in 50s
Lint / JS (eslint) (pull_request) Successful in 30s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 55s
Test / Python Tests (pytest) (pull_request) Successful in 50s
Lint / JS (eslint) (push) Successful in 16m17s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Trace a cord: pick a panel port, press Start, and unplug the cord at the panel. The page polls a new admin-only endpoint that reads every switch port's state from UniFi (cached 2 s), shows the one port that dropped with a button to record the cable, and confirms when it's plugged back in. Several ports dropping at once, or none within 3 minutes, is explained rather than guessed at. Mismatch alerts: the monitor runs the cutsheet check every poll. Each mismatched installed run (wrong neighbor, no link, missing port, port conflict) keeps one cable_mismatch event on its switch, resolved when fixed, and opens a P4 ticket after cutsheet.mismatch_ticket_hours (default 24, 0 never). Suppressing the switch or port stops the ticket. Also fixes buttons with the hidden attribute still showing, which left a Delete button on the new-cable form. Closes #12 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
b9412ff6ba |
Add cutsheets: planned cabling checked against discovery
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m36s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m40s
Lint / Python (flake8) (pull_request) Successful in 52s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m13s
Test / Python Tests (pytest) (pull_request) Successful in 1m15s
A new Cutsheet page records where every cable is meant to go and compares it with what Gandalf discovers. - Inventory for what discovery can't see: patch panels, wall jacks, shelves and rack positions. Panels and jacks pass through front to rear. - Cables with two endpoints, ID, type, length, color, status (planned, installed, dark, retired) and notes; the far end may be unterminated. - Each cable's full run is traced through panels and jacks, and runs ending on a switch port are checked against its discovered neighbor (LLDP, client table, or a DAC serial seen at both ends): matches, wrong neighbor, no link, missing port, port conflict, unverified, idle. - Undocumented links: live switch ports no cable mentions, one click to add with what Gandalf already knows. Port panels show the planned cable. - Labels to make: cable IDs and panel-port labels not yet applied, with a print view, for a handheld label maker. - CSV export, and all-or-nothing import that upserts by cable ID. - Cables, panels and jacks appear in the dashboard search. Editing needs the admin group and a JSON request body. Every change is written to cutsheet_history in the same transaction. Tables are created on first use. Refs #12 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
5c4e4dc099 |
Only trust Authelia identity headers from the proxy
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 1m9s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m33s
Test / Python Tests (pytest) (push) Successful in 1m54s
Lint / Python (flake8) (pull_request) Successful in 1m19s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m16s
Test / Python Tests (pytest) (pull_request) Successful in 1m29s
Remote-User/Name/Email/Groups were read from every request, so a LAN host connecting to the container directly could claim any user and group. Add auth.trusted_proxies and ignore those headers unless the request came from one of them: the X-Real-IP the local nginx sets, or the peer address when gunicorn is reached directly. With nothing configured, nobody is trusted. Rejected attempts are logged, and /api/avatar now uses the same check. The container's nginx site blanks the same headers for non-NPM sources (pve-infra 4e3ab7c). Closes #3 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
051e70b82b |
Draw realistic front panels for every device model
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 57s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m7s
Lint / Python (flake8) (pull_request) Successful in 59s
Test / Python Tests (pytest) (push) Successful in 1m22s
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m7s
Test / Python Tests (pytest) (pull_request) Successful in 1m28s
Replace the port blocks on device pages with SVG faceplates traced from reference images: Dream Machine Pro, USW Pro 24 PoE, USW Aggregation, USW Flex, USW Flex Mini, USP PDU Pro and UPS 2U Pro. Port LEDs use each model's documented colors, and ports show a cable or module when up. Remove SWITCH_LAYOUTS, which had wrong data: the aggregation switch was numbered across the rows instead of odd over even, and the USW Flex had an SFP cage it doesn't have. Models without a faceplate use plain blocks. Show PDU and UPS outlets with on/off state and auto power-cycle, and let the UPS page show its panel even though it reports no ports. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
bdcfb76c25 |
Move the port inspector onto device pages
Lint / JS (eslint) (push) Successful in 1m14s
Lint / Python (flake8) (push) Successful in 2m12s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m3s
Test / Python Tests (pytest) (push) Successful in 1m11s
Lint / Python (flake8) (pull_request) Successful in 1m1s
Lint / JS (eslint) (pull_request) Successful in 10s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 56s
Test / Python Tests (pytest) (pull_request) Successful in 1m5s
Replace the all-switches Inspector page with a per-device front panel, port table and detail panel. /inspector now redirects to the dashboard, and /device/<name>#port-<n> links directly to a port. Restore neighbor names after UniFi's LLDP change: read local_port_idx and resolve neighbors by MAC using Prometheus NIC data, UniFi devices and the wired client table. This also brings back Run Diagnostics on server ports, which depends on a named neighbor. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
e32499b7f6 |
Add AT&T modem monitoring and device pages; replace Link Debug
Lint / Python (flake8) (pull_request) Successful in 2m6s
Lint / JS (eslint) (pull_request) Successful in 18s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 2m11s
Test / Python Tests (pytest) (pull_request) Successful in 2m20s
Lint / JS (eslint) (push) Successful in 10s
Lint / Python (flake8) (push) Successful in 1m58s
Lint / Notify on failure (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m58s
Lint / Deploy (push) Successful in 4s
Test / Python Tests (pytest) (push) Successful in 58s
Modem and WAN: - Poll the BGW320 status pages read-only for light levels, PON and WAN state, with a WAN / Fiber panel, 7-day Rx trend, and alerts on WAN down, optical limits, and Rx drift - Read WAN outages and Smart Power restarts from the UniFi system log, since outages can be over between 5 minute polls Device pages: - Add device search to the dashboard and a page per host, switch, router, AP, PDU, or modem - Move all Link Debug data into expandable rows there; /links redirects - Collect UDM ports and UniFi device details (firmware, load, WAN, outlets) - Reorder the dashboard Monitoring fixes: - Alert when a configured host stops reporting: its series disappear rather than reporting down, so a dead host never raised an alert - Alert on Prometheus outages instead of blanking the dashboard - Treat a failed Pulse ping as unknown rather than host unreachable - Stop new switch ports reporting lifetime bytes as one interval's rate - Run database sessions in UTC: other server time zones shifted displayed ages and timed suppression expiries Also log every avatar 404 reason, add a favicon, and correct the WAN link labels (1G on Port 9, not 10G SFP+). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |