pro-max-faceplates
4
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
0f4e129c20 |
Rack: drawn fronts for the NVR and server cases
Lint / JS (eslint) (push) Successful in 15s
Security / Python Security (bandit) (push) Successful in 1m5s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Python (flake8) (pull_request) Successful in 53s
Test / Python Tests (pytest) (push) Successful in 1m0s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 53s
Test / Python Tests (pytest) (pull_request) Successful in 57s
Items Gandalf has no live faceplate for can pick a Front drawing: the UniFi NVR Pro (drawn from the CC0 NetBox devicetype-library image), the Sliger CX4712 4U and Rosewill RSV-L4500U 4U cases (from driveAtlas's layouts), and generic 1U/2U/4U servers. The power light shows the linked device's live status. They export with the rest of the rack. New cutsheet_items column chassis, added on first use. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
c50e1f8322 |
Rack: front and rear mounting, rack settings in the page
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 49s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 51s
Lint / Python (flake8) (pull_request) Successful in 55s
Test / Python Tests (pytest) (push) Successful in 1m4s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 52s
Test / Python Tests (pytest) (pull_request) Successful in 55s
Items are mounted from the front, the rear, or full depth. On a 4-post rack a front and a rear item can share a unit; a full-depth one takes both sides, and the rear view shows its back. Overlaps are checked per side. Shelf contents take the shelf's side. A Front / Rear switch flips the drawing. Racks are saved in Gandalf (new cutsheet_racks table) and edited on the rack page by admins: name, height, notes, add and delete. Renaming moves the rack's items; saving the first rack carries over the items of the config default it replaces. Config racks remain the fallback. Faceplates are stretched to the full width only when the drawing is close to the slot's proportions, so the PDU is not squashed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
bdd68a397d |
Rack: link items to devices, shelves, several racks, export; fix layout and light mode
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 48s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 49s
Lint / Python (flake8) (pull_request) Successful in 51s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 50s
Test / Python Tests (pytest) (pull_request) Successful in 53s
Cutsheet items gain a "Gandalf device" link, so an item named after the product (UDM-Pro) shows the live device's faceplate, ports and status. Cable checks, suggestions, tickets and the device page treat an item and its linked device as one. Without this, product-named items drew as bare name plates. Items can sit on a shelf instead of a rack unit; the shelf draws what is on it with live status. Items have a rack, the page shows a tab per rack (config "racks"), and a rack can be downloaded as SVG or PNG. The rack is centred, long runs of empty units fold into one band (with a toggle), every device fills the 19" width, the UPS shows its front only, and the rack keeps its own palette so it reads in light mode. New cutsheet_items columns rack, shelf and device are added on first use. Deleting a shelf, or making it something else, is refused while it holds items; renaming it carries over. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |
||
|
|
f655836446 |
Add a rack drawing (/rack)
Lint / JS (eslint) (push) Successful in 7s
Lint / Python (flake8) (push) Successful in 50s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 50s
Test / Python Tests (pytest) (push) Successful in 1m2s
Lint / Python (flake8) (pull_request) Successful in 52s
Lint / JS (eslint) (pull_request) Successful in 7s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m42s
Test / Python Tests (pytest) (pull_request) Successful in 2m2s
The rack front is drawn from the rack units on cutsheet items. Switches with a faceplate use it, with live port state; patch panels get a generic panel with port labels; everything else is a labelled plate. Each documented port shows its cutsheet state, and hovering a port lights up every port on the same cable run (through patch panels) and names the cables. Clicking opens the switch port or the cable. Overlapping items and items past the top of the rack are listed instead of drawn over another; where two claim the same top unit, the first one recorded wins. rack.units sets the height (default 42). /api/rack builds on the cutsheet view; cutsheet.rack_layout and cutsheet.port_marks hold the placement and per-port logic. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> |