Power: flag frozen outlet watts, draw the SmartPower Strip
Lint / JS (eslint) (push) Successful in 14s
Lint / Python (flake8) (push) Successful in 1m3s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Security / Python Security (bandit) (push) Successful in 1m9s
Test / Python Tests (pytest) (push) Successful in 1m29s
Lint / Python (flake8) (pull_request) Successful in 1m9s
Lint / JS (eslint) (pull_request) Successful in 14s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (pull_request) Successful in 1m26s
Test / Python Tests (pytest) (pull_request) Successful in 1m48s

UniFi can keep serving one frozen set of USP PDU Pro outlet readings for hours
while the unit's total stays live (seen on prod: every outlet at 120.661 V with
the same watts all session, summing to 321 W of a live 593 W total). The monitor
now notices when a power unit's loaded outlet readings have not changed for 15
minutes and marks them stale. The topology page shows "stale" instead of watts,
the power badge says "fed", and a "to look at" chip says since when; the device
page marks the readings too.

Adds a UP6 (USP-Strip) faceplate traced from Ubiquiti's datasheet render: three
facing pairs of US outlets, four USB-C ports (outlet 7), the LED and the cord.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
jaredandClaude Opus 5.5 committed 2026-11-14 22:46:04 -05:00
1 parent 206175df39
commit 60d892badb
8 files changed
+189 -18

No files matched your search

+46
View File
@@ -485,6 +485,52 @@ class TestWanIncident:
assert not mon.tickets.create.called and not mon.tickets.comment.called
class TestStaleOutletReadings:
@staticmethod
def _pdu(w1=20.622, w2=0.0):
return {'RPDU': {'outlets': [
{'index': 1, 'power_w': w1, 'current_a': 0.322},
{'index': 2, 'power_w': w2, 'current_a': 0.0},
{'index': 3, 'power_w': None, 'current_a': None}, # USB: never metered
]}}
def _collector(self):
c = monitor.LinkStatsCollector.__new__(monitor.LinkStatsCollector)
c._outlet_readings = {}
return c
def test_readings_frozen_past_the_limit_are_stale(self):
c = self._collector()
c._mark_stale_outlets(self._pdu(), 1000.0)
later = self._pdu()
c._mark_stale_outlets(later, 1000.0 + c.OUTLET_STALE_AFTER_S)
assert later['RPDU']['outlets_stale_since'] == '1970-01-01 00:16:40 UTC'
assert [o.get('stale') for o in later['RPDU']['outlets']] == [True, True, None]
def test_moving_readings_are_live(self):
c = self._collector()
c._mark_stale_outlets(self._pdu(), 1000.0)
c._mark_stale_outlets(self._pdu(w1=21.0), 1000.0 + c.OUTLET_STALE_AFTER_S - 1)
later = self._pdu(w1=21.0)
c._mark_stale_outlets(later, 1000.0 + c.OUTLET_STALE_AFTER_S + 60)
assert 'outlets_stale_since' not in later['RPDU']
assert not any(o.get('stale') for o in later['RPDU']['outlets'])
def test_idle_outlets_reading_zero_are_not_stale(self):
c = self._collector()
c._mark_stale_outlets(self._pdu(w1=0.0), 1000.0)
later = self._pdu(w1=0.0)
c._mark_stale_outlets(later, 1000.0 + 10 * c.OUTLET_STALE_AFTER_S)
assert 'outlets_stale_since' not in later['RPDU']
def test_unmetered_strip_is_left_alone(self):
c = self._collector()
strip = {'USP Strip': {'outlets': [{'index': 1, 'power_w': None}]}}
c._mark_stale_outlets(strip, 1000.0)
c._mark_stale_outlets(strip, 1000.0 + 10 * c.OUTLET_STALE_AFTER_S)
assert 'outlets_stale_since' not in strip['USP Strip'] and 'USP Strip' not in c._outlet_readings
class TestUnifiDeviceDetail:
def test_parses_string_stats_and_outlets(self):
d = monitor.UnifiClient._device_detail({