Cutsheet: port names in UniFi that no longer fit, document a cable from topology
Lint / JS (eslint) (push) Successful in 23s
Lint / Python (flake8) (push) Successful in 1m10s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Lint / Python (flake8) (pull_request) Successful in 53s
Lint / JS (eslint) (pull_request) Successful in 11s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (push) Successful in 1m26s
Test / Python Tests (pytest) (push) Successful in 1m49s
Security / Python Security (bandit) (pull_request) Successful in 2m17s
Test / Python Tests (pytest) (pull_request) Successful in 2m12s

- topology.port_name_report: switch port names that no longer fit what is
  plugged in, as a checklist with suggested names: named after the wrong
  device, named after a device that moved to another port, named with nothing
  plugged in (and who was last seen there), and still "Port N" with a known
  device on it. Ports named after a device that is only off are left alone.
  Gandalf only reports; it never renames anything in UniFi.
- /api/cutsheet returns it as port_names; the cutsheet page shows it as
  "Port names in UniFi", grouped, with a summary chip.
- The topology cable panel's "not documented" gets a "document it" link that
  opens the cutsheet's new-cable form with both ends, the NIC and DAC filled
  in; /cutsheet?... now takes b_device, b_port and cable_type.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-11-15 13:48:52 -05:00
co-authored by Claude Opus 5.5
parent d6fcddb6fc
commit 4dfabce2fb
9 changed files with 248 additions and 3 deletions
+10 -1
View File
@@ -353,7 +353,16 @@ can view it; only the `admin` group can edit, and every change is logged with wh
cables in one port). Runs that end at a jack are *unverified* while linked and *idle* when not.
Planned, dark and retired cables aren't checked.
- **Undocumented links**: live switch ports no cable mentions, with an Add button that pre-fills
what Gandalf knows. Each switch port panel also shows its planned cable, or links to add one.
what Gandalf knows. Each switch port panel also shows its planned cable, or links to add one. On
the topology page, a cable with no record has a **document it** link that opens this form with both
ends (and the NIC, and DAC when it is one) filled in. `/cutsheet?a_device=&a_port=&b_device=&b_port=&cable_type=`
opens it the same way.
- **Port names in UniFi**: a checklist of switch port names that no longer fit what is plugged in:
named after the wrong device, named after a device that has moved to another port, named but with
nothing plugged in (with who was last seen there), and still "Port N" with a known device on it
(folded). Each comes with a suggested name: the device, the device and NIC for a server with two
cables, "Uplink" or "Downlink to X" between switches. A port named after a device that is only
switched off is left alone. Rename them in UniFi yourself; Gandalf never changes UniFi.
- **Labels to make**: cable IDs (one per cord end) and panel-port labels not yet stuck on, sized for
typing on a handheld label maker. Tick each off once it's applied; **Print list** prints just this.
- **CSV**: export, and import that adds or updates cables by ID. A file with any invalid row imports