Topology: power map, what each outlet feeds
Lint / JS (eslint) (push) Successful in 21s
Lint / Python (flake8) (push) Successful in 2m36s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Test / Python Tests (pytest) (push) Successful in 2m46s
Lint / JS (eslint) (pull_request) Successful in 15s
Lint / Python (flake8) (pull_request) Successful in 2m14s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (push) Successful in 1m33s
Security / Python Security (bandit) (pull_request) Successful in 54s
Test / Python Tests (pytest) (pull_request) Successful in 1m3s
Lint / JS (eslint) (push) Successful in 21s
Lint / Python (flake8) (push) Successful in 2m36s
Lint / Notify on failure (push) Skipped
Lint / Deploy (push) Skipped
Test / Python Tests (pytest) (push) Successful in 2m46s
Lint / JS (eslint) (pull_request) Successful in 15s
Lint / Python (flake8) (pull_request) Successful in 2m14s
Lint / Notify on failure (pull_request) Skipped
Lint / Deploy (pull_request) Skipped
Security / Python Security (bandit) (push) Successful in 1m33s
Security / Python Security (bandit) (pull_request) Successful in 54s
Test / Python Tests (pytest) (pull_request) Successful in 1m3s
- Each PDU, UPS and power strip card lists its outlets that feed something, draw power or are off, with live watts. Each device fed gets a power badge with what it draws. Hovering a power card or a device draws its feeds as dotted lines and keeps both ends lit. - What an outlet feeds: a saved assignment, else the outlet's UniFi name when it names a device (or the modem), else a MAC in its name that belongs to a host NIC (the monitor's host_macs) or UniFi device. - Admins click an outlet to set what it feeds, nothing, or automatic. Saved in a new power_feeds table (created with the cutsheet tables); PUT /api/topology/power/<device>/<outlet>, admin and JSON only, with the device, outlet and target checked. UniFi is never changed. - An outlet that is off but feeds something is listed under "to look at". - Power gear is shown by default again, now that it has something to say. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
dcf5fdf4cc
commit
415d2222e7
10 files changed
+492
-22
No files matched your search
@@ -212,15 +212,23 @@ servers along the bottom. Power gear (PDU, UPS, power strip) sits in a rail on t
|
||||
"Downlink to X" with X on the other end never flag.
|
||||
- **Alerts**: a device with active alerts (not suppressed) gets a ring and a count in its worst
|
||||
severity colour, and the NIC it is about is marked.
|
||||
- **Power**: each PDU, UPS and power strip card lists its outlets that feed something, draw power or
|
||||
are off, with live watts; each device it feeds shows a ⚡ badge with what it draws. Hover a power
|
||||
card or a device to draw its feeds. An outlet that is off but feeds something is listed above the
|
||||
diagram. What an outlet feeds comes from, in order: an assignment saved here, the outlet's name in
|
||||
UniFi when it names a device ("storage-01", "Dream Machine Pro", "AT&T Modem" for the modem), or a
|
||||
MAC in its name that belongs to a host NIC or UniFi device. Admins click an outlet to set what it
|
||||
feeds, set it to nothing, or go back to automatic. Assignments are kept in Gandalf (table
|
||||
`power_feeds`); Gandalf never renames outlets in UniFi. API: `PUT /api/topology/power/<device>/<outlet>`
|
||||
with `{"target": "<device>"}`, `""` for nothing or `null` for automatic.
|
||||
- Click a device for its page, or a port on a faceplate for that port. Click a cable for its details:
|
||||
both ends, speed, cable type and module, traffic each way and how busy it is, errors and drops, and
|
||||
its cutsheet record. Hovering a device traces its path to the internet.
|
||||
- Drag to pan, scroll or pinch to zoom, **Fit** (or `0`) to see everything, `+` and `-` to zoom. Show
|
||||
unknown devices grouped, one by one or not at all. **Server 1G links** (off by default) adds each
|
||||
server's slower second cable, its management link; **Power gear** (off by default) adds the PDU, UPS
|
||||
and power strip. Traffic labels and dimming everything without an alert can be switched too. The
|
||||
server's slower second cable, its management link; **Power gear** shows or hides the power rail. Traffic labels and dimming everything without an alert can be switched too. The
|
||||
filters are remembered per browser. Refreshes every 30 seconds without moving the view.
|
||||
- API: `GET /api/topology` returns `{nodes, links, warnings, updated}` (see `topology.py`).
|
||||
- API: `GET /api/topology` returns `{nodes, links, power, warnings, updated}` (see `topology.py`).
|
||||
|
||||
### Health check (`/health`)
|
||||
No login needed. Returns 200 when the database answers and the monitor has completed a check recently,
|
||||
|
||||
Reference in new issue