Files
driveAtlas/diagnose-drives.sh

60 lines
1.8 KiB
Bash
Raw Normal View History

#!/bin/bash
# Drive Atlas Diagnostic Script
# Run this on each server to gather PCI path information
echo "=== Server Information ==="
echo "Hostname: $(hostname)"
echo "Date: $(date)"
echo ""
echo "=== All /dev/disk/by-path/ entries ==="
ls -la /dev/disk/by-path/ | grep -v "part" | sort
echo ""
echo "=== Organized by PCI Address ==="
for path in /dev/disk/by-path/*; do
if [ -L "$path" ]; then
# Skip partitions
if [[ "$path" =~ -part[0-9]+$ ]]; then
continue
fi
basename_path=$(basename "$path")
target=$(readlink -f "$path")
device=$(basename "$target")
echo "Path: $basename_path"
echo " -> Device: $device"
# Try to get size
if [ -b "$target" ]; then
size=$(lsblk -d -n -o SIZE "$target" 2>/dev/null)
echo " -> Size: $size"
fi
# Try to get SMART info for model
if command -v smartctl >/dev/null 2>&1; then
model=$(sudo smartctl -i "$target" 2>/dev/null | grep "Device Model\|Model Number" | cut -d: -f2 | xargs)
if [ -n "$model" ]; then
echo " -> Model: $model"
fi
fi
echo ""
fi
done
echo "=== PCI Devices with Storage Controllers ==="
lspci | grep -i "storage\|raid\|sata\|sas\|nvme"
echo ""
echo "=== Current Block Devices ==="
lsblk -d -o NAME,SIZE,TYPE,TRAN | grep -v "rbd\|loop"
echo ""
echo "=== Recommendations ==="
echo "1. Note the PCI addresses (e.g., 0c:00.0) of your storage controllers"
echo "2. For each bay, physically identify which drive is in it"
echo "3. Match the PCI path pattern to the bay number"
echo "4. Example: pci-0000:0c:00.0-ata-1 might be bay 1 on controller 0c:00.0"